SMD code -C95
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
11 parts are printed -C95
Not sure which one you have?
Answer up to 4 quick questions and these 11 parts are ranked, with a meter test that settles it. It works on a dead part too.
SN74LVC1G34DCKSOT-353Logic gate, 5 pins, Texas InstrumentsLogic gateSOT-3535 pinsTexas Instruments
- What it is
- Logic gate
- Maker
- Texas Instruments
- Package
- SOT-353
- Pins
- 5
- Details
- Single Buffer Gate
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SN74LVC2G34DCKSOT-363Logic gate, 6 pins, Texas InstrumentsLogic gateSOT-3636 pinsTexas Instruments
- What it is
- Logic gate
- Maker
- Texas Instruments
- Package
- SOT-363
- Pins
- 6
- Details
- Dual Buffer Gate
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
BCV64SOT-1434 pins, NexperiaNot recordedSOT-1434 pinsNexperia
- What it is
- Not recorded
- Maker
- Nexperia
- Package
- SOT-143
- Pins
- 4
- Details
- Si-pnp: Dual, 30V, 100mA, 250mW, B=110..800, >100MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
CMHD3595SOD-1232 pins, Central SemiconductorNot recordedSOD-1232 pinsCentral Semiconductor
- What it is
- Not recorded
- Maker
- Central Semiconductor
- Package
- SOD-123
- Pins
- 2
- Details
- Diode: Sw, 150V, 150mA, 400mW, Vf<1V(200mA), <8pF
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
LN61FC2912MSOT-23Voltage supervisor, 3 pins, Shanghai Natlinear ElectronicsVoltage supervisorSOT-233 pinsShanghai Natlinear Electronics
- What it is
- Voltage supervisor
- Maker
- Shanghai Natlinear Electronics
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.9V±2%, +Reset PPO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LN61FC2912PSOT-89Voltage supervisor, 3 pins, Shanghai Natlinear ElectronicsVoltage supervisorSOT-893 pinsShanghai Natlinear Electronics
- What it is
- Voltage supervisor
- Maker
- Shanghai Natlinear Electronics
- Package
- SOT-89
- Pins
- 3
- Details
- Voltage detector IC: 2.9V±2%, +Reset PPO, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LN3526C2912MSOT-143Voltage supervisor, 4 pins, Shanghai Natlinear ElectronicsVoltage supervisorSOT-1434 pinsShanghai Natlinear Electronics
- What it is
- Voltage supervisor
- Maker
- Shanghai Natlinear Electronics
- Package
- SOT-143
- Pins
- 4
- Details
- Voltage detector IC: 2.9V±2%, -Reset PPO, -MR, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
SN74LVC1G34DBVSOT-353Logic gate, 5 pins, Texas InstrumentsLogic gateSOT-3535 pinsTexas Instruments
- What it is
- Logic gate
- Maker
- Texas Instruments
- Package
- SOT-353
- Pins
- 5
- Details
- Single Buffer Gate
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC61FC2912MSOT-23Voltage supervisor, 3 pins, TorexVoltage supervisorSOT-233 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23
- Pins
- 3
- Details
- CMOS-IC: Voltage Detector 2,9V, Reset Push-pull output, 200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC61FC2912PSOT-89Voltage supervisor, 3 pins, TorexVoltage supervisorSOT-893 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-89
- Pins
- 3
- Details
- CMOS-IC: Voltage Detector 2,9V, Reset Push-pull output, 200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC61HC2912MRSOT-23Voltage supervisor, 3 pins, TorexVoltage supervisorSOT-233 pinsTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 2.9V±2%, -Reset PPO, Rdt=50..200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as -C95
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with -C95
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.