Skip to content

SMD code 2045

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

6 parts are printed 2045

Not sure which one you have?

Answer up to 4 quick questions and these 6 parts are ranked, with a meter test that settles it. It works on a dead part too.

all SOT-23-6, 6 pins. What differs:

  • 2SD2045SOT-23-6Transistor, SeCoSTransistorSeCoS
    What it is
    Transistor
    Maker
    SeCoS
    Package
    SOT-23-6
    Pins
    6
    Details
    Bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • BL2045-6LSOT-23-6Complementary transistor pair (NPN and PNP), Galaxy MicroelectronicsComplementary transistor pair (NPN and PNP)Galaxy Microelectronics
    What it is
    Complementary transistor pair (NPN and PNP)
    Maker
    Galaxy Microelectronics
    Package
    SOT-23-6
    Pins
    6
    Details
    40V, 1.5A, General Purpose NPN+PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor pair.

  • CJ2045SOT-23-6Transistor, JSCJTransistorJSCJ
    What it is
    Transistor
    Maker
    JSCJ
    Package
    SOT-23-6
    Pins
    6
    Details
    Bipolar transistor, NPN PNP
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • TBL2045-6LSOT-23-6Complementary transistor pair (NPN and PNP), Galaxy MicroelectronicsComplementary transistor pair (NPN and PNP)Galaxy Microelectronics
    What it is
    Complementary transistor pair (NPN and PNP)
    Maker
    Galaxy Microelectronics
    Package
    SOT-23-6
    Pins
    6
    Details
    40V, 1.5A, General Purpose Dual NPN+PNP Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor pair.

  • YFW2045FSOT-23-6Transistor, YFWTransistorYFW
    What it is
    Transistor
    Maker
    YFW
    Package
    SOT-23-6
    Pins
    6
    Details
    Bipolar transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Bipolar transistor.

  • ZXTC2045E6SOT-23-6Diodes IncorporatedNot recordedDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23-6
    Pins
    6
    Details
    T1 npn T2 pnp comp pair 30V
    Source
    Published code list

    Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor pair

Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.