SMD code 56P
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
56P on a chip capacitor
56 pF
56 pF capacitor
The p is both the decimal point and the unit: 56 pF.
Check it with a meter
Lift one end and measure it on a capacitance range. A good one reads close to 56 pF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. A failed one usually reads near 0 Ω, or a steady low resistance, on the ohms range, often from a crack. On the board a shorted capacitor shorts its whole rail. A failed reading does not change what to fit: the marking still says 56 pF.
On a transistor or diode body (SOT-23-5, SOT-23, SMA), 56P is a part code instead. Those parts are listed below.
3 parts are printed 56P
Not sure which one you have?
Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.
MFPZ56SOD-123FZener diode, 2 pins, Taitron ComponentsZener diodeSOD-123F2 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SOD-123F
- Pins
- 2
- Details
- SMD Zener Diodes (Two Terminals) - 800mW
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
BSR19SOT-233 pinsNot recordedSOT-233 pinsNot recorded
- What it is
- Not recorded
- Maker
- Not recorded
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: Sw, 160V, 600mA, 250mW, B>60, 300
- Source
- Published code list
Is it dead? The meter test is below: This part.
BZD27C56PSOD-123FTVS diode, 2 pins, PanjitTVS diodeSOD-123F2 pinsPanjit
- What it is
- TVS diode
- Maker
- Panjit
- Package
- SOD-123F
- Pins
- 2
- Details
- 47V, 150W, Surface Mount TVS
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 56P
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with 56P
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.