Skip to content

SMD marking

MC

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

2 parts are printed MC

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

all Infineon. What differs:

  • BFS17PRF transistor
    What it is
    RF transistor
    Maker
    Infineon
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BGB540RF amplifier (MMIC)
    What it is
    RF amplifier (MMIC)
    Maker
    Infineon
    Package
    Not recorded
    Pins
    Not recorded
    Source
    From the manufacturer's datasheet

    Is it dead?

    Voltage, board powered, on the output pin that the bias resistor or choke feeds.

    Working, it reads

    The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

    Dead, it reads

    • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
    • Output pin at the full supply voltage: open inside, no current flowing.
    On the board:
    Measured on the board with power on; the bias network is part of the reading.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The figures depend on the part and its bias resistor. The datasheet gives both.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

8 more parts are printed with a code easy to misread as MC

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

  • BZX384-B22printed M6SOD-323Zener diode, 2 pins, Nexperia

    Printed M6 on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5256printed M6SOD-123Zener diode, 2 pins, Vishay

    Printed M6 on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    30 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5256-Gprinted M6SOD-123Zener diode, 2 pins, Vishay

    Printed M6 on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    30 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • NX2301Pprinted MGSOT-23P-channel MOSFET, 3 pins, Nexperia

    Printed MG on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

    What it is
    P-channel MOSFET
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    20 V, 2 A P-channel Trench MOSFET
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
    • No body diode at all: failed open.
    On the board:
    On the board the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S9015printed M6SOT-23PNP transistor, 3 pins, JSCJ

    Printed M6 on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

    What it is
    PNP transistor
    Maker
    JSCJ
    Package
    SOT-23
    Pins
    3
    Details
    Bipolar transistor, PNP
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMBJ28Aprinted MGSMBTVS diode, 2 pins, Vishay

    Printed MG on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMB
    Pins
    2
    Details
    600 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMBJ28CAprinted MGSMBTVS diode, 2 pins, Vishay

    Printed MG on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMB
    Pins
    2
    Details
    600 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 1 more part has no package on record
    • SMBG28Aprinted MGTVS diode, Vishay

      Printed MG on the part. Easy to misread as MC. Check that character with a loupe before you order anything.

      What it is
      TVS diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      600 W TVS diode, unidirectional
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board:
      On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

17 more parts have codes that begin with MC

Codes that begin with MC

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • PZ1AL8V7B-AUprinted MCHSOD-123FZener diode, 2 pins, Panjit

    Printed MCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZS51A9V1CSprinted MCHSOD-323Zener diode, 2 pins, Panjit

    Printed MCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TPSMF4L43Aprinted MC1SOD-123FTVS diode, 2 pins, Diotec

    Printed MC1. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Diotec
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Transient Voltage Suppressor Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • LM4041BIDCKprinted MGUSOT-353Voltage reference, 5 pins, Texas Instruments

    Printed MGU. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage reference
    Maker
    Texas Instruments
    Package
    SOT-353
    Pins
    5
    Details
    Precision Micropower Shunt Voltage Reference
    Source
    From the manufacturer's datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMDT4413printed M6ASOT-363Transistor, 6 pins, Panjit

    Printed M6A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Transistor
    Maker
    Panjit
    Package
    SOT-363
    Pins
    6
    Details
    Bipolar transistor
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • P6SMB51Aprinted MGJSMBTVS diode, 2 pins, Taiwan Semiconductor

    Printed MGJ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Taiwan Semiconductor
    Package
    SMB
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • P6SMB51AHprinted MGJSMBTVS diode, 2 pins, Taiwan Semiconductor

    Printed MGJ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Taiwan Semiconductor
    Package
    SMB
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SM6T33Aprinted MG7SMBTVS diode, 2 pins, Vishay

    Printed MG7. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMB
    Pins
    2
    Details
    600 W TVS diode, unidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SM6T33CAprinted MG7SMBTVS diode, 2 pins, Vishay

    Printed MG7. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMB
    Pins
    2
    Details
    600 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TPSMF4L54Aprinted MG1SOD-123FTVS diode, 2 pins, Diotec

    Printed MG1. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    TVS diode
    Maker
    Diotec
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Transient Voltage Suppressor Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 7 more parts have no package on record
    • PZ1AH8V7Bprinted MCHZener diode, Panjit

      Printed MCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZ1AH8V7B-AUprinted MCHZener diode, Panjit

      Printed MCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS519V1BASprinted MCHZener diode, Panjit

      Printed MCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS519V1BAS-AUprinted MCHZener diode, Panjit

      Printed MCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS5210BCHprinted MCHZener diode, Panjit

      Printed MCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOMR62818printed M62818MOSFET, Alpha & Omega Semiconductor

      Printed M62818. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOMR66922printed M66922MOSFET, Alpha & Omega Semiconductor

      Printed M66922. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.