Skip to content

SMD code R1502

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

R1502 on a chip inductor

0.15 µH

0.15 µH inductor

The R stands in for the decimal point, in microhenries: 0.15 µH. SMD power inductors below 10 µH are printed this way. The same marking also reads as 0.15 pF on a capacitor, and nothing in the code says which; the body of the part does.

Other readings of the same characters, most likely first

  • 0.15 pF capacitor

Check it with a meter

Measure it on an LCR meter, out of circuit. A good one reads close to 0.15 µH. An ohmmeter only shows the winding resistance, which is a fraction of an ohm on a good part and says nothing about the value; open circuit means the winding has failed. Shorted turns still read near 0 Ω on an ohmmeter, so only the LCR meter, or an identical part beside it, shows them. A failed reading does not change what to fit: the marking still says 0.15 µH.

On a transistor or diode body (SOT-23-6), R1502 is a part code instead. Those parts are listed below.

The only part printed R1502 in our tables

GSFR1502

What it is
N-channel MOSFET
Maker
Good-Ark
Package
SOT-23-6
Pins
6
Details
N-channel MOSFET, 150 V
Source
Manufacturer datasheet

Is it dead?

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Datasheetfor GSFR1502, opens in a new tab

Was it this one?

Did you find your part?

Open this in the search to correct a character or try another package.