Skip to content

SMD code SMA64A

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

SMA64A is a part number in our tables

SMA64A

What it is
TVS diode
Maker
Compact Technology, Master Instrument Corporation of Shanghai
Package
SMA
Pins
2
Details
Transient voltage supressor: Vrwm=64.0V, Vbr=71.10..78.60V, Ipp=3.88A, 400W(1ms)
Source
Published code list

Is it dead?

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes printed on it

Each maker prints its own code, and each code has a page of its own.

  • A64ACompact Technology, SMA
  • 64VAMaster Instrument Corporation of Shanghai, SMA

The only part printed SMA64A in our tables

PSMA64A

What it is
Not recorded
Maker
Phi
Package
SMA
Pins
2
Details
TVS: 64V, 3,6A, 400W (1ms)
Source
Published code list

Is it dead?

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Was it this one?

Did you find your part?

Open this in the search to correct a character or try another package.