SMD code T224
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
T224 on a chip capacitor
220 nF, 50 V
220 nF, 50 V tantalum capacitor
A moulded tantalum capacitor: 224 is the capacitance in picofarads (220 nF) and T is the rated-voltage code (50 V). Makers disagree on the letter for 50 V: T at Kyocera AVX and Vishay, H at ROHM.
Check it with a meter
Lift one end and measure it on a capacitance range. A good one reads close to 220 nF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. It is polarised: the band on the body marks the positive end, and a tantalum fitted backwards fails short, sometimes with a flame. A failed tantalum usually reads near 0 Ω both ways, often with a burnt or cracked body. A failed reading does not change what to fit: the marking still says 220 nF, 50 V. Fit the same capacitance at the same or a higher voltage.
On a transistor or diode body (SOT-23-6), T224 is a part code instead. Those parts are listed below.
The only part printed T224 in our tables
TRV24-2LC
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- SOT-23-6
- Pins
- 6
- Details
- Ultra Low Capacitance Steering Diode/Thyristor Array
- Source
- Manufacturer datasheet
Is it dead?
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Was it this one?
Did you find your part?
Open this in the search to correct a character or try another package.