SMD marking

YGS

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and YG was searched.

4 parts are printed YGs

Not sure which one you have?

Answer up to 4 quick questions and these 4 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BZT52C10SOD-123Zener diode, 2 pins, Vishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52C10-GSOD-123Zener diode, 2 pins, Vishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    5210 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SMAJ28CASMATVS diode, 2 pins, Vishay
    What it is
    TVS diode
    Maker
    Vishay
    Package
    SMA
    Pins
    2
    Details
    400 W TVS diode, bidirectional
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 1 more part has no package on record
    • BSS314PEP-channel MOSFET, Infineon
      What it is
      P-channel MOSFET
      Maker
      Infineon
      Package
      Not recorded
      Pins
      Not recorded
      Details
      P-channel enhancement mode Field-Effect Transistor (FET), -30 V, SOT-23
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

8 more parts are printed with a code easy to misread as YGs

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

  • BSS315Pprinted YCsSOT-23P-channel MOSFET, 3 pins, Infineon

    Printed YCs on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

    What it is
    P-channel MOSFET
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Details
    P-channel enhancement mode Field-Effect Transistor (FET), -30 V, SOT-23
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
    • No body diode at all: failed open.
    On the board:
    On the board the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52C3V9printed Y6SOD-123Zener diode, 2 pins, Vishay

    Printed Y6 on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52C3V9-Gprinted Y6SOD-123Zener diode, 2 pins, Vishay

    Printed Y6 on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    523.9 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52C6V8printed YCSOD-123Zener diode, 2 pins, Vishay

    Printed YC on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52C6V8-Gprinted YCSOD-123Zener diode, 2 pins, Vishay

    Printed YC on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    526.8 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX84-C18printed Y6SOT-23Zener diode, 3 pins, Nexperia

    Printed Y6 on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    18 V approx. ±5% voltage regulator (Zener) diode
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX84C18printed Y6SOT-23Zener diode, 3 pins, Diotec

    Printed Y6 on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOT-23
    Pins
    3
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 1 more part has no package on record
    • BZX584B43printed Y6.Zener diode, Taiwan Semiconductor

      Printed Y6. on the part. Easy to misread as YGS. Check that character with a loupe before you order anything.

      What it is
      Zener diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

12 more parts have codes that begin with YGs

Codes that begin with YGs

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • TLV431BQDCKprinted YGUSOT-363Voltage reference, 6 pins, Texas Instruments

    Printed YGU. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Voltage reference
    Maker
    Texas Instruments
    Package
    SOT-363
    Pins
    6
    Details
    Low-Voltage Adjustable Precision Shunt Regulator
    Source
    From the manufacturer's datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZ1AL18B-AUprinted YCHSOD-123FZener diode, 2 pins, Panjit

    Printed YCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PZS51A19CSprinted YCHSOD-323Zener diode, 2 pins, Panjit

    Printed YCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 9 more parts have no package on record
    • AOY66620printed Y66620MOSFET, Alpha & Omega Semiconductor

      Printed Y66620. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOY66919printed Y66919MOSFET, Alpha & Omega Semiconductor

      Printed Y66919. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOY66920printed Y66920MOSFET, Alpha & Omega Semiconductor

      Printed Y66920. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOY66923printed Y66923MOSFET, Alpha & Omega Semiconductor

      Printed Y66923. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      MOSFET
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Medium-voltage (40-400 V) MOSFET
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted.
      • No body diode at all: failed open.
      On the board:
      On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZ1AH18Bprinted YCHZener diode, Panjit

      Printed YCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZ1AH18B-AUprinted YCHZener diode, Panjit

      Printed YCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS5119BASprinted YCHZener diode, Panjit

      Printed YCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS5119BAS-AUprinted YCHZener diode, Panjit

      Printed YCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PZS5222BCHprinted YCHZener diode, Panjit

      Printed YCH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Open this in the search to correct a character or try another package.