Skip to content

1 part is printed 22. 2 printed with a similar-looking code.

Not sure which one you have?

Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.

The only part printed 22 in this package in our tables

DTC123EE

What it is
Digital transistor (NPN, resistors built in)
Maker
JSCJ
Package
Not recorded
Pins
Not recorded
Details
Digital transistor (bias resistors built in), NPN
Source
From the manufacturer's datasheet

Is it dead?

Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

Working, it reads

Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

Dead, it reads

  • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
  • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
  • Base to emitter near 0 Ω: failed short.
On the board:
On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
Watch for:
On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread

These parts are printed with a character that is easy to misread as what you typed. The odd one out is marked on each.

  • ESDSU5V0AE1printed ZZESD protection diode, JSCJ

    Printed ZZ on the part. Easy to misread as 22. Check that character with a loupe before you order anything.

    What it is
    ESD protection diode
    Maker
    JSCJ
    Package
    Not recorded
    Pins
    Not recorded
    Details
    ESD protection diode, VRWM 5 V
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board:
    On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TSU1M60Hprinted Z2Schottky diode, Taiwan Semiconductor

    Printed Z2 on the part. Easy to misread as 22. Check that character with a loupe before you order anything.

    What it is
    Schottky diode
    Maker
    Taiwan Semiconductor
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Rectifier schottky
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

21 more parts have codes that begin with 22

Codes that begin with 22

For a marking with its end worn or burnt off. Each one shows its full printed code.

  • BZT52B22printed 22VBSOD-123FZener diode, 2 pins, Taiwan Semiconductor

    Printed 22VB. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZT52C22printed 22VZSOD-123FZener diode, 2 pins, Taiwan Semiconductor

    Printed 22VZ. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5221Bprinted Z2V4SOD-123FZener diode, 2 pins, Taiwan Semiconductor

    Printed Z2V4. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5250Bprinted Z20VSOD-123FZener diode, 2 pins, Taiwan Semiconductor

    Printed Z20V. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5251Bprinted Z22VSOD-123FZener diode, 2 pins, Taiwan Semiconductor

    Printed Z22V. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5252Bprinted Z24VSOD-123FZener diode, 2 pins, Taiwan Semiconductor

    Printed Z24V. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ5254Bprinted Z27VSOD-123FZener diode, 2 pins, Taiwan Semiconductor

    Printed Z27V. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123F
    Pins
    2
    Details
    SMD Planar Zener Diodes
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board:
    On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • 1SMB3EZ22printed 22BZener diode, Panjit

      Printed 22B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 1SMB3EZ22-AUprinted 22BZener diode, Panjit

      Printed 22B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Panjit
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ22Aprinted 22AZener diode, Vishay

      Printed 22A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      22 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ22Bprinted 22BZener diode, Vishay

      Printed 22B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      22 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ22Cprinted 22CZener diode, Vishay

      Printed 22C. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      22 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PLZ22Dprinted 22DZener diode, Vishay

      Printed 22D. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      22 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SMPZ3922Bprinted 22BZener diode, Vishay

      Printed 22B. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Vishay
      Package
      Not recorded
      Pins
      Not recorded
      Details
      7.5 V Zener diode
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SS220ALHprinted 220ALHSchottky diode, Taiwan Semiconductor

      Printed 220ALH. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Schottky diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Rectifier schottky
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPS562201DDCprinted 2201DC-DC converter, 6 pins, Texas Instruments

      Printed 2201. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      DC-DC converter
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      6
      Details
      4.5V to 17V Input, 2A Synchronous Step-Down Voltage Regulator in SOT-23
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPS562208DDCprinted 2208DC-DC converter, 6 pins, Texas Instruments

      Printed 2208. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      DC-DC converter
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      6
      Details
      4.5V to 17V Input, 2A Synchronous Step-Down Voltage Regulator in SOT-23
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TPS562231DRLprinted 2231DC-DC converter, 6 pins, Texas Instruments

      Printed 2231. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      DC-DC converter
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      6
      Details
      4.5-V to 17-V Input, 2-A Synchronous Step-Down Buck Converter in SOT563
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ2264QI-20printed Z2264QINDC-DC converter, Alpha & Omega Semiconductor

      Printed Z2264QIN. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      DC-DC converter
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Synchronous buck regulator
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AOZ2264QI-30printed Z2264QIMDC-DC converter, Alpha & Omega Semiconductor

      Printed Z2264QIM. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      DC-DC converter
      Maker
      Alpha & Omega Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Synchronous buck regulator
      Source
      From the manufacturer's datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BZX584B10printed 2Z9Zener diode, Taiwan Semiconductor

      Printed 2Z9. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

      What it is
      Zener diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      From the manufacturer's datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board:
      On the board this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it