Skip to content

SMD code search: identify a part by its marking

1 part in SOT-343 is printed 27S. 2 printed with a similar-looking code.

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

4 pins, all ABLIC.

  • S-1335C26-N4T1U3SOT-343
    What it is
    Not recorded
    Maker
    ABLIC
    Package
    SOT-343
    Pins
    4
    Details
    equivalent [2.6V LDO]
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 1 more part has no package on record. Nothing rules it out, so it stays.
    • S-1335C26-A4T2U3
      What it is
      Not recorded
      Maker
      ABLIC
      Package
      Not recorded
      Pins
      4
      Details
      equivalent [2.6V LDO]
      Source
      Published code list

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

2 more parts are printed with a code easy to misread as 27S: none in SOT-343, 2 with no package on record

Printed with a code easy to misread

One character differs, and it is one that is easy to confuse under a lamp. The odd one out is marked on each.

2 parts have no package on record. Nothing rules them out, so they stay.

  • SGM40679AXGprinted 275Load switch, 6 pins, SG MicroLoad switch6 pinsSG Micro

    Printed 275 on the part. Easy to misread as 27S. Check that character with a loupe before you order anything.

    What it is
    Load switch
    Maker
    SG Micro
    Package
    Not recorded
    Pins
    6
    Details
    Over-Voltage Protection Switch For the USB Type-C Differential Pairs
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground.

    Working, it reads

    Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

    Dead, it reads

    • Output at the input voltage while switched off: the pass element has shorted.
    • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
    On the board:
    An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • VRH2751NVprinted 275LDO regulator, AnaSemLDO regulatorNot recordedAnaSem

    Printed 275 on the part. Easy to misread as 27S. Check that character with a loupe before you order anything.

    What it is
    LDO regulator
    Maker
    AnaSem
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Linear voltage regulator IC: LDO, 2.75V±1%, 250mA, +CE
    Source
    Published code list

    Is it dead?

    Voltage, board powered, black probe on ground. Then ohms with the power off.

    Working, it reads

    Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

    Dead, it reads

    • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
    • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
    • Power off, input to output near 0 Ω: shorted.
    On the board:
    An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
    Compare:
    The same regulator on another rail or another board shows the right voltages and the right resistances.
    Watch for:
    Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

7 more parts have codes that begin with 27S: none in SOT-343, 7 with no package on record

Codes that begin with 27S

For a marking with its end worn or burnt off. Each one shows its full printed code.

7 parts have no package on record. Nothing rules them out, so they stay.

  • CSZA7.5Aprinted Z7.5AZener diode, LRCZener diodeNot recordedLRC

    Printed Z7.5A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    LRC
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Zener diode, VZ Min 7.13 V, VZ Nom 7.5 V, VZ Max 7.88 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CSZA75Aprinted Z75AZener diode, LRCZener diodeNot recordedLRC

    Printed Z75A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    LRC
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Zener diode, VZ Min 71.25 V, VZ Nom 75 V, VZ Max 78.75 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • G2275AM52Dprinted 275ADC-DC converter, 7 pins, Global Mixed-mode TechnologyDC-DC converter7 pinsGlobal Mixed-mode Technology

    Printed 275A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    DC-DC converter
    Maker
    Global Mixed-mode Technology
    Package
    Not recorded
    Pins
    7
    Details
    4A, 2.4MHz, COT Synchronous Step-Down Converter
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • G2275AM52Uprinted 275ADC-DC converter, 7 pins, Global Mixed-mode TechnologyDC-DC converter7 pinsGlobal Mixed-mode Technology

    Printed 275A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    DC-DC converter
    Maker
    Global Mixed-mode Technology
    Package
    Not recorded
    Pins
    7
    Details
    4A, 2.4MHz, COT Synchronous Step-Down Converter
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MTSZ5267BWSprinted Z75VZener diode, SeCoSZener diodeNot recordedSeCoS

    Printed Z75V. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    SeCoS
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S-CSZA7.5Aprinted Z7.5AZener diode, LRCZener diodeNot recordedLRC

    Printed Z7.5A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    LRC
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Zener diode, VZ Min 7.13 V, VZ Nom 7.5 V, VZ Max 7.88 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • S-CSZA75Aprinted Z75AZener diode, LRCZener diodeNot recordedLRC

    Printed Z75A. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Zener diode
    Maker
    LRC
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Zener diode, VZ Min 71.25 V, VZ Nom 75 V, VZ Max 78.75 V
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Get WhatSMD on Google Play