Skip to content

SMD code search: identify a part by its marking

12 parts in SOT-523 are printed 24.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ADTC114EE-HFSOT-523Digital transistor (NPN, resistors built in), 3 pins, ComchipDigital transistor (NPN, resistors built in)3 pinsComchip
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    Comchip
    Package
    SOT-523
    Pins
    3
    Details
    NPN digital transistor, R1 10 kΩ, R2 10 kΩ
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTC114EESOT-523Digital transistor (NPN, resistors built in), 3 pins, Formosa MicrosemiDigital transistor (NPN, resistors built in)3 pinsFormosa Microsemi
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    Formosa Microsemi
    Package
    SOT-523
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTC114EE3HZGTLSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)3 pinsHXY
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    HXY
    Package
    SOT-523
    Pins
    3
    Details
    Digital transistor (bias resistors built in)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTC114EECRSOT-523Digital transistor (resistors built in), 3 pins, SeCoSDigital transistor (resistors built in)3 pinsSeCoS
    What it is
    Digital transistor (resistors built in)
    Maker
    SeCoS
    Package
    SOT-523
    Pins
    3
    Details
    Digital (resistor-equipped) transistor
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • DTC114EET1GSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)3 pinsHXY
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    HXY
    Package
    SOT-523
    Pins
    3
    Details
    Digital transistor (bias resistors built in)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • HDTC114EE3HZGTLSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)3 pinsHXY
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    HXY
    Package
    SOT-523
    Pins
    3
    Details
    Digital transistor (bias resistors built in)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • HMUN5211T1GSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)3 pinsHXY
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    HXY
    Package
    SOT-523
    Pins
    3
    Details
    Digital transistor (bias resistors built in)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • HRN1302LFSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)3 pinsHXY
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    HXY
    Package
    SOT-523
    Pins
    3
    Details
    Digital transistor (bias resistors built in)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MUN5211T1GSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)3 pinsHXY
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    HXY
    Package
    SOT-523
    Pins
    3
    Details
    Digital transistor (bias resistors built in)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • RN1302,LFSOT-523Digital transistor (NPN, resistors built in), 3 pins, HXYDigital transistor (NPN, resistors built in)3 pinsHXY
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    HXY
    Package
    SOT-523
    Pins
    3
    Details
    Digital transistor (bias resistors built in)
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TDTC114EESOT-523Digital transistor (NPN, resistors built in), 3 pins, Galaxy MicroelectronicsDigital transistor (NPN, resistors built in)3 pinsGalaxy Microelectronics
    What it is
    Digital transistor (NPN, resistors built in)
    Maker
    Galaxy Microelectronics
    Package
    SOT-523
    Pins
    3
    Details
    50V, 50mA, NPN Bipolar Digital Transistor
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CRZ24SOT-5233 pins, ToshibaNot recorded3 pinsToshiba
    What it is
    Not recorded
    Maker
    Toshiba
    Package
    SOT-523
    Pins
    3
    Details
    Z-diode: 21.6..26.47V, 700mW
    Source
    Published code list

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 38 more parts have no package on record. Nothing rules them out, so they stay.
    • BGS8424RF switch, 8 pins, NXPRF switch8 pinsNXP
      What it is
      RF switch
      Maker
      NXP
      Package
      Not recorded
      Pins
      8
      Details
      1 General description 2 Features and benefits 3 Applications
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CDBMT240-HFSchottky diode, ComchipSchottky diodeNot recordedComchip
      What it is
      Schottky diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      40 V, 2 A Schottky barrier diode
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CHSBDJGPSchottky diode, ChenmkoSchottky diodeNot recordedChenmko
      What it is
      Schottky diode
      Maker
      Chenmko
      Package
      Not recorded
      Pins
      Not recorded
      Details
      SCHOTTKY BARRIER RECTIFIER, 40 V, 2.0 A
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CHSDBDJGP-ASchottky diode, ChenmkoSchottky diodeNot recordedChenmko
      What it is
      Schottky diode
      Maker
      Chenmko
      Package
      Not recorded
      Pins
      Not recorded
      Details
      SCHOTTKY BARRIER RECTIFIER, 40 V, 2.0 A
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MHSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MH-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MHTSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MHT-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MSSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MS-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MSTSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • FM240-MST-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • KRC402E-RTK/PDigital transistor (NPN, resistors built in), HXYDigital transistor (NPN, resistors built in)Not recordedHXY
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      HXY
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Digital transistor (bias resistors built in)
      Source
      Manufacturer datasheet

      Is it dead?

      Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

      Working, it reads

      Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
      • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
      • Base to emitter near 0 Ω: failed short.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
      Watch for:
      On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • LMBR240ET1GSchottky diode, LRCSchottky diodeNot recordedLRC
      What it is
      Schottky diode
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky diode, VR 40 V, IF 2 A, VF Max 0.5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • NUF2450MUESD protection diode, onsemiESD protection diodeNot recordedonsemi
      What it is
      ESD protection diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      2 Line EMI Filter with ESD Protection
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • NX5P2924UKLoad switch, NXPLoad switchNot recordedNXP
      What it is
      Load switch
      Maker
      NXP
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Logic controlled high-side power switch
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground.

      Working, it reads

      Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

      Dead, it reads

      • Output at the input voltage while switched off: the pass element has shorted.
      • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
      On the board:
      An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • PSBD3DH40V2HSchottky diode, PrisemiSchottky diodeNot recordedPrisemi
      What it is
      Schottky diode
      Maker
      Prisemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky diode, 40 V, 2 A
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • RBR2VWM40ASchottky diode, ROHMSchottky diodeNot recordedROHM
      What it is
      Schottky diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diode
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • RBR2VWM40ATFSchottky diode, ROHMSchottky diodeNot recordedROHM
      What it is
      Schottky diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diode (AEC-Q101 qualified)
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • S-LMBR240ET1GSchottky diode, LRCSchottky diodeNot recordedLRC
      What it is
      Schottky diode
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky diode, VR 40 V, IF 2 A, VF Max 0.5 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM2036S-1.6XXDH4GLDO regulator, 4 pins, SG MicroLDO regulator4 pinsSG Micro
      What it is
      LDO regulator
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      4
      Details
      1.6 V output, 300mA, Low Power and Low Dropout RF Linear Regulator
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SM240HTSchottky diode, SeCoSSchottky diodeNot recordedSeCoS
      What it is
      Schottky diode
      Maker
      SeCoS
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SS2040HESchottky diode, Galaxy MicroelectronicsSchottky diodeNot recordedGalaxy Microelectronics
      What it is
      Schottky diode
      Maker
      Galaxy Microelectronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      2A, 40V, Surface Mount Schottky Barrier Rectifiers
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SSU24SSchottky diode, YFWSchottky diodeNot recordedYFW
      What it is
      Schottky diode
      Maker
      YFW
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • USFZ24VZener diode, KECZener diodeNot recordedKEC
      What it is
      Zener diode
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 02DZ2.4XZener diode, ToshibaZener diodeNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 2.28..2.50V, Iz=5mA, Zz=100, 200mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 02DZ2.4ZZener diode, ToshibaZener diodeNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 2.40..2.60V, Iz=5mA, Zz=100, 200mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 2SC50063 pins, California Eastern LaboratoriesNot recorded3 pinsCalifornia Eastern Laboratories
      What it is
      Not recorded
      Maker
      California Eastern Laboratories
      Package
      Not recorded
      Pins
      3
      Details
      npn RF fT 4.5GHz @3V 7mA
      Source
      Published code list

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BZY55-C24Zener diode, Taiwan SemiconductorZener diodeNot recordedTaiwan Semiconductor
      What it is
      Zener diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 22.80..25.20V, Izt=5mA, Zzt=80, 500mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CDZ55C24Zener diode, Crownpo TechnologyZener diodeNot recordedCrownpo Technology
      What it is
      Zener diode
      Maker
      Crownpo Technology
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 22.80..25.20V, Zzt=80, Izt=5mA, 500mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CDZ55C24SZener diode, Crownpo TechnologyZener diodeNot recordedCrownpo Technology
      What it is
      Zener diode
      Maker
      Crownpo Technology
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 22.80..25.20V, Zzt=80, Izt=5mA, 500mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CDZ55C24TZener diode, Crownpo TechnologyZener diodeNot recordedCrownpo Technology
      What it is
      Zener diode
      Maker
      Crownpo Technology
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 22.80..25.20V, Zzt=80, Izt=5mA, 200mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CMZ24Zener diode, ToshibaZener diodeNot recordedToshiba
      What it is
      Zener diode
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Z-diode: 24V±5%, 2W
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CTZ55C24Zener diode, Compact TechnologyZener diodeNot recordedCompact Technology
      What it is
      Zener diode
      Maker
      Compact Technology
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 22.80..25.20V, Izt=5mA, Zzt=80, 500mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CZRNC55C24-GZener diode, ComchipZener diodeNot recordedComchip
      What it is
      Zener diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 22.80..25.20V, Zt=80, Izt=5mA, 500mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CZRSC55C24-GZener diode, ComchipZener diodeNot recordedComchip
      What it is
      Zener diode
      Maker
      Comchip
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 22.80..25.20V, Zt=80, Izt=5mA, 500mW
      Source
      Published code list

      Is it dead?

      Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

      Working, it reads

      About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways, forward too: failed open.
      • Holds well off its rated voltage on the supply test: drifted.
      • A soft knee, or a voltage that creeps on the supply test: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • DTC114EROHMNot recordedNot recordedROHM
      What it is
      Not recorded
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Published code list

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • DTC114EB3 pins, ROHMNot recorded3 pinsROHM
      What it is
      Not recorded
      Maker
      ROHM
      Package
      Not recorded
      Pins
      3
      Source
      Published code list

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

31 more parts are not listed here. Type more of the code to narrow the list.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Get WhatSMD on Google Play
  • Coming soon to the App Store