Skip to content

SMD code search: identify a part by its marking

7 parts in SOT-523 are printed L4.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BAT54STSOT-523Schottky diode, 3 pins, onsemiSchottky diode3 pinsonsemi
    What it is
    Schottky diode
    Maker
    onsemi
    Package
    SOT-523
    Pins
    3
    Details
    0.2A, 30V, Surface Mount Small Signal Schottky Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAT54ST-CSOT-523Schottky diode, 3 pins, SeCoSSchottky diode3 pinsSeCoS
    What it is
    Schottky diode
    Maker
    SeCoS
    Package
    SOT-523
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAT54ST-HFSOT-523Schottky diode, 3 pins, ComchipSchottky diode3 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SOT-523
    Pins
    3
    Details
    30 V, 0.2 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAT54STCR-CSOT-523Schottky diode, 3 pins, SeCoSSchottky diode3 pinsSeCoS
    What it is
    Schottky diode
    Maker
    SeCoS
    Package
    SOT-523
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • GSBAT54STSOT-523Schottky diode, 3 pins, Good-ArkSchottky diode3 pinsGood-Ark
    What it is
    Schottky diode
    Maker
    Good-Ark
    Package
    SOT-523
    Pins
    3
    Details
    Schottky diode, 30 V, 200 mA
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TBAT54STSOT-523Schottky diode, 3 pins, Galaxy MicroelectronicsSchottky diode3 pinsGalaxy Microelectronics
    What it is
    Schottky diode
    Maker
    Galaxy Microelectronics
    Package
    SOT-523
    Pins
    3
    Details
    0.2A, 30V, Surface Mount Small Signal Schottky Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX84C6V2TSOT-523Zener diode, 3 pins, Silicon-Based TechnologyZener diode3 pinsSilicon-Based Technology
    What it is
    Zener diode
    Maker
    Silicon-Based Technology
    Package
    SOT-523
    Pins
    3
    Details
    zener 150mW 6.2V
    Source
    Published code list

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 43 more parts have no package on record. Nothing rules them out, so they stay.
    • BAT54TWSSchottky diode, Taitron ComponentsSchottky diodeNot recordedTaitron Components
      What it is
      Schottky diode
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diodes (Multiple Terminals)
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BB179LXVaricap diode, 2 pins, NXPVaricap diode2 pinsNXP
      What it is
      Varicap diode
      Maker
      NXP
      Package
      Not recorded
      Pins
      2
      Details
      UHF variable capacitance diode
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.6 to 0.9 V anode to cathode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • EMI9404MUESD protection diode, onsemiESD protection diodeNot recordedonsemi
      What it is
      ESD protection diode
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      PRAETORIAN  III 4-Channel EMI Array with ESD Protection
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • KTC4075NPN transistor, KECNPN transistorNot recordedKEC
      What it is
      NPN transistor
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • LDTA143YET1GDigital transistor (PNP, resistors built in), LRCDigital transistor (PNP, resistors built in)Not recordedLRC
      What it is
      Digital transistor (PNP, resistors built in)
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Digital transistor (bias resistors built in), PNP, IC 100 mA, VCEO 50 V
      Source
      Manufacturer datasheet

      Is it dead?

      Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

      Working, it reads

      Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
      • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
      • Base to emitter near 0 Ω: failed short.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
      Watch for:
      On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SGM2045-4.20XGLDO regulator, 4 pins, SG MicroLDO regulator4 pinsSG Micro
      What it is
      LDO regulator
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      4
      Details
      4.20 V output, 300mA, Low VIN, Ultra-Low Noise and High PSRR Linear Regulator
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SL14-MHSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SL14-MHTSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SL14-MSSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SL14-MS-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SL14-MSTSchottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SL14-MST-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedFormosa Microsemi
      What it is
      Schottky diode
      Maker
      Formosa Microsemi
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TCR2LN13LDO regulator, ToshibaLDO regulatorNot recordedToshiba
      What it is
      LDO regulator
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      TCR2LN series
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TSCD24WSchottky diode, Taitron ComponentsSchottky diodeNot recordedTaitron Components
      What it is
      Schottky diode
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Low Profile Chip Type Schottky Rectifier
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TSD023-54WSSchottky diode, Taitron ComponentsSchottky diodeNot recordedTaitron Components
      What it is
      Schottky diode
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diodes (Two Terminals)
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TSD023-54WTSchottky diode, Taitron ComponentsSchottky diodeNot recordedTaitron Components
      What it is
      Schottky diode
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diodes (Two Terminals)
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 2SC1623AL43 pins, RenesasNot recorded3 pinsRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      3
      Source
      Published code list

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • 2SC2812-L4onsemiNot recordedNot recordedonsemi
      What it is
      Not recorded
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn: GP, AF, 55V, 150mA, 200mW, B=90..180, 100MHz
      Source
      Published code list

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP8821N-34GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2%, -Reset ODO, H-free
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP8821N-34GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2%, -Reset ODO, H-free
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP8821N-34PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2%, -Reset ODO
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP8821N-34PSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2%, -Reset ODO
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • BFS37A3 pins, Diodes IncorporatedNot recorded3 pinsDiodes Incorporated
      What it is
      Not recorded
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      3
      Source
      Published code list

      Is it dead?

      Diode range and ohms range, part lifted.

      Working, it reads

      Depends on what it is. The datasheet, or an identical part, says.

      Dead, it reads

      • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
      • Open between every pair of pins: failed open, or a part that reads open when working.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CD1607-B140Schottky diode, BournsSchottky diodeNot recordedBourns
      What it is
      Schottky diode
      Maker
      Bourns
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-diode: Schottky, Rect, 40V, 1A, Vf=0.5V(1A), 110pF
      Source
      Published code list

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CD1607-B140LSchottky diode, BournsSchottky diodeNot recordedBourns
      What it is
      Schottky diode
      Maker
      Bourns
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-diode: Schottky, Rect, 40V, 1A, Vf=0.4V(1A), 110pF
      Source
      Published code list

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • CDSOT236-T246 pins, BournsNot recorded6 pinsBourns
      What it is
      Not recorded
      Maker
      Bourns
      Package
      Not recorded
      Pins
      6
      Details
      TVS Diode Array (24V unidirectional)
      Source
      Published code list

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • EC95808N34C7IVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
      What it is
      Voltage supervisor
      Maker
      E-CMOS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2%, -Reset ODO
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • EC95808N34C7SVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
      What it is
      Voltage supervisor
      Maker
      E-CMOS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2%, -Reset ODO
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • HD74LV1G32ACMRenesasNot recordedNot recordedRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-input OR gate
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • HD74LV1G32ACMERenesasNot recordedNot recordedRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-Logic: 2-input OR gate
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • HD74LV1G32AVSRenesasNot recordedNot recordedRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-input OR gate
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • HD74LV1G32AVSERenesasNot recordedNot recordedRenesas
      What it is
      Not recorded
      Maker
      Renesas
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-Logic: 2-input OR gate
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • IXD5120C342NR-GVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2% -Reset PPO
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • KTC601E-YKECNot recordedNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN transistor: Dual GP, 50V, 150mA, 100mW, B=120..240, 80MHz
      Source
      Published code list

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • KTC601U-YKECNot recordedNot recordedKEC
      What it is
      Not recorded
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      NPN transistor: Dual GP, 50V, 150mA, 100mW, B=120..240, 80MHz
      Source
      Published code list

      Is it dead?

      Diode range, part lifted or its base leg off the pad.

      Working, it reads

      From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
      • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
      • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
      • A reading the wrong way round, where it should be open: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • NC7SP86LFairchild SemiconductorNot recordedNot recordedFairchild Semiconductor
      What it is
      Not recorded
      Maker
      Fairchild Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-input EXCLUSIVE-OR gate
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • NL17SZ32XV5T2Logic gate, onsemiLogic gateNot recordedonsemi
      What it is
      Logic gate
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Single 2-Input OR Gate
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • R1211D100ANisshinbo Micro DevicesNot recordedNot recordedNisshinbo Micro Devices
      What it is
      Not recorded
      Maker
      Nisshinbo Micro Devices
      Package
      Not recorded
      Pins
      Not recorded
      Details
      VR-IC: PWM step-up DC-DC converter, ULVO=2,2V, 700KHz
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • RN1105FSDigital transistor (NPN, resistors built in), ToshibaDigital transistor (NPN, resistors built in)Not recordedToshiba
      What it is
      Digital transistor (NPN, resistors built in)
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-npn-Digi: Sw, 20V, 50mA, 50mW, R1/R2=2.2k/47k
      Source
      Published code list

      Is it dead?

      Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

      Working, it reads

      Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

      Dead, it reads

      • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
      • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
      • Base to emitter near 0 Ω: failed short.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
      Watch for:
      On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SSCD204ZowieNot recordedNot recordedZowie
      What it is
      Not recorded
      Maker
      Zowie
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Si-diode: Schottky Barrier Rectifier, 40V, 2A, Vf<0,5V(2A)
      Source
      Published code list

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • XC6GN1402HRTorexNot recordedNot recordedTorex
      What it is
      Not recorded
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS-IC: Voltage Detector 1,4V, Reset Open drain output
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • XC61CN1402NVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.4V±2%, +Reset ODO
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • XC6120C34NVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.4V±2%, CMOS +Reset PPO
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

2 more parts are not listed here. Type more of the code to narrow the list.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Get WhatSMD on Google Play
  • Coming soon to the App Store