Skip to content

1 part is printed 5AS. 1 printed with a similar-looking code.

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

The only part printed 5AS in our tables

PEC3808AS-AU

What it is
ESD protection diode
Maker
Panjit
Package
SOD-123
Pins
2
Source
From the manufacturer's datasheet

Is it dead?

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board:
On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread

This part is printed with a character that is easy to misread as what you typed. The odd one out is marked on each.

  • BSS123Nprinted SAsSOT-23N-channel MOSFET, 3 pins, Infineon

    Printed SAs on the part. Easy to misread as 5AS. Check that character with a loupe before you order anything.

    What it is
    N-channel MOSFET
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Details
    N-Channel Small Signal MOSFET 100 V in SOT23 package
    Source
    From the manufacturer's datasheet

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
    • No body diode at all: failed open.
    On the board:
    On the board the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it