Skip to content

1 part is printed F12.

The only part printed F12 in our tables

ESDUNF12VI1

What it is
ESD protection diode
Maker
JSCJ
Package
SOD-323
Pins
2
Details
ESD protection diode, VRWM 12 V
Source
From the manufacturer's datasheet

Is it dead?

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board:
On the board, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.