Skip to content

SMD code search: identify a part by its marking

94 parts are printed T2.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ABAV20W-HFSOD-123Switching diode, 2 pins, ComchipSwitching diodeSOD-1232 pinsComchip
    What it is
    Switching diode
    Maker
    Comchip
    Package
    SOD-123
    Pins
    2
    Details
    200 V, 200 mA switching diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ABAV20WS-HFSOD-323Switching diode, 2 pins, ComchipSwitching diodeSOD-3232 pinsComchip
    What it is
    Switching diode
    Maker
    Comchip
    Package
    SOD-323
    Pins
    2
    Details
    200 V, 200 mA switching diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20LSOD-882Switching diode, 2 pins, Galaxy MicroelectronicsSwitching diodeSOD-8822 pinsGalaxy Microelectronics
    What it is
    Switching diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-882
    Pins
    2
    Details
    0.2A, 150V, Surface Mount Small Signal Switching Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20P-CSOD-123Switching diode, 2 pins, SeCoSSwitching diodeSOD-1232 pinsSeCoS
    What it is
    Switching diode
    Maker
    SeCoS
    Package
    SOD-123
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WSOD-123Switching diode, 2 pins, Galaxy MicroelectronicsSwitching diodeSOD-1232 pinsGalaxy Microelectronics
    What it is
    Switching diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-123
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20W-FLSOD-123FSwitching diode, 2 pins, Formosa MicrosemiSwitching diodeSOD-123F2 pinsFormosa Microsemi
    What it is
    Switching diode
    Maker
    Formosa Microsemi
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20W-GSOD-123Switching diode, 2 pins, Taiwan SemiconductorSwitching diodeSOD-1232 pinsTaiwan Semiconductor
    What it is
    Switching diode
    Maker
    Taiwan Semiconductor
    Package
    SOD-123
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20W-G3-08SOD-123Switching diode, 2 pins, HXYSwitching diodeSOD-1232 pinsHXY
    What it is
    Switching diode
    Maker
    HXY
    Package
    SOD-123
    Pins
    2
    Details
    Switching diode, 250 V, 0.2 A
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20W-HFSOD-123Switching diode, 2 pins, ComchipSwitching diodeSOD-1232 pinsComchip
    What it is
    Switching diode
    Maker
    Comchip
    Package
    SOD-123
    Pins
    2
    Details
    200 V, 200 mA switching diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20W-Q1SOD-123FSwitching diode, 2 pins, Formosa MicrosemiSwitching diodeSOD-123F2 pinsFormosa Microsemi
    What it is
    Switching diode
    Maker
    Formosa Microsemi
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WSSOD-323Switching diode, 2 pins, Formosa MicrosemiSwitching diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Switching diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WS-7-FSOD-323Switching diode, 2 pins, HXYSwitching diodeSOD-3232 pinsHXY
    What it is
    Switching diode
    Maker
    HXY
    Package
    SOD-323
    Pins
    2
    Details
    Switching diode, 200 V, 0.2 A
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WS-FLSOD-323Switching diode, 2 pins, Formosa MicrosemiSwitching diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Switching diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WS-FL-Q1SOD-323Switching diode, 2 pins, Formosa MicrosemiSwitching diodeSOD-3232 pinsFormosa Microsemi
    What it is
    Switching diode
    Maker
    Formosa Microsemi
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WS-HFSOD-323Switching diode, 2 pins, ComchipSwitching diodeSOD-3232 pinsComchip
    What it is
    Switching diode
    Maker
    Comchip
    Package
    SOD-323
    Pins
    2
    Details
    200 V, 200 mA switching diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WSFLSOD-323Switching diode, 2 pins, YFWSwitching diodeSOD-3232 pinsYFW
    What it is
    Switching diode
    Maker
    YFW
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BAV20WTSOD-523Switching diode, 2 pins, YFWSwitching diodeSOD-5232 pinsYFW
    What it is
    Switching diode
    Maker
    YFW
    Package
    SOD-523
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BCX18SOT-23PNP transistor, 3 pins, Taitron ComponentsPNP transistorSOT-233 pinsTaitron Components
    What it is
    PNP transistor
    Maker
    Taitron Components
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX84-C27SOT-23Zener diode, 3 pins, NexperiaZener diodeSOT-233 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOT-23
    Pins
    3
    Details
    27 V approx. ±5% voltage regulator (Zener) diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • BZX384-C10SOD-323Zener diode, 2 pins, NexperiaZener diodeSOD-3232 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CHEMT2GPSOT-563Dual PNP transistor, 6 pins, ChenmkoDual PNP transistorSOT-5636 pinsChenmko
    What it is
    Dual PNP transistor
    Maker
    Chenmko
    Package
    SOT-563
    Pins
    6
    Details
    Dual Silicon Transistor, 50 V, 150 mA
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.

    Working, it reads

    Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • CPDQT12VHT-HFSOD-882ESD protection diode, 2 pins, ComchipESD protection diodeSOD-8822 pinsComchip
    What it is
    ESD protection diode
    Maker
    Comchip
    Package
    SOD-882
    Pins
    2
    Details
    12 V bidirectional ESD protection diode
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MM3Z2V4SSOD-323Zener diode, 2 pins, onsemiZener diodeSOD-3232 pinsonsemi
    What it is
    Zener diode
    Maker
    onsemi
    Package
    SOD-323
    Pins
    2
    Details
    2.4V, 400mW, Surface Mount Zener Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MM5Z2V4SSOD-523Zener diode, 2 pins, onsemiZener diodeSOD-5232 pinsonsemi
    What it is
    Zener diode
    Maker
    onsemi
    Package
    SOD-523
    Pins
    2
    Details
    Zener Voltage Regulators MM5ZxxxST1G Series, SZMM5ZxxxST1G Series
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMBD6050SOT-23Switching diode, 3 pins, Taitron ComponentsSwitching diodeSOT-233 pinsTaitron Components
    What it is
    Switching diode
    Maker
    Taitron Components
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • MMSZ2V7SOD-123Zener diode, 2 pins, onsemiZener diodeSOD-1232 pinsonsemi
    What it is
    Zener diode
    Maker
    onsemi
    Package
    SOD-123
    Pins
    2
    Details
    Zener Voltage Regulators MMSZxxxT1G Series, SZMMSZxxxT1G Series
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • PUMD14SOT-363Digital transistor (PNP, resistors built in), 6 pins, NexperiaDigital transistor (PNP, resistors built in)SOT-3636 pinsNexperia
    What it is
    Digital transistor (PNP, resistors built in)
    Maker
    Nexperia
    Package
    SOT-363
    Pins
    6
    Details
    50 V, 100 mA NPN/PNP resistor-equipped transistor; R1 = 47 kΩ, R2 = open
    Source
    Manufacturer datasheet

    Is it dead?

    Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.

    Working, it reads

    Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
    • From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
    • Base to emitter near 0 Ω: failed short.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
    Watch for:
    On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SM220FLSOD-123FSchottky diode, 2 pins, SeCoSSchottky diodeSOD-123F2 pinsSeCoS
    What it is
    Schottky diode
    Maker
    SeCoS
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • SY20118ADFCDFNDC-DC converter, SilergyDC-DC converterDFNNot recordedSilergy
    What it is
    DC-DC converter
    Maker
    Silergy
    Package
    DFN
    Pins
    Not recorded
    Details
    High-Efficiency, 1MHz, 4A Synchronous Step-Down Regulator DS_SY20118A Rev. 1.0 1 © 2021 Silergy Corp. All Rights Reserve
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TBAV20LSOD-882Switching diode, 2 pins, Galaxy MicroelectronicsSwitching diodeSOD-8822 pinsGalaxy Microelectronics
    What it is
    Switching diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-882
    Pins
    2
    Details
    0.2A, 150V, Surface Mount Small Signal Switching Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • TBAV20WSSOD-323Switching diode, 2 pins, Galaxy MicroelectronicsSwitching diodeSOD-3232 pinsGalaxy Microelectronics
    What it is
    Switching diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-323
    Pins
    2
    Details
    0.2A, 150V, Surface Mount Small Signal Switching Diodes
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways: failed open.
    • A reading the wrong way round as well: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • UMT2NSOT-363PNP transistor, 6 pins, JSCJPNP transistorSOT-3636 pinsJSCJ
    What it is
    PNP transistor
    Maker
    JSCJ
    Package
    SOT-363
    Pins
    6
    Details
    Bipolar transistor, PNP
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, part lifted or its base leg off the pad.

    Working, it reads

    Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

    Dead, it reads

    • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
    • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
    • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
    • A reading the wrong way round, where it should be open: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • ESD1006B7V0SOD-882ESD protection diode, 2 pins, YFWESD protection diodeSOD-8822 pinsYFW
    What it is
    ESD protection diode
    Maker
    YFW
    Package
    SOD-882
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range, from the protected line to ground, part lifted if you can.

    Working, it reads

    A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

    Dead, it reads

    • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
    • A reading both ways on a one-way part: leaky.
    • A one-way part open both ways: failed open.
    On the board
    , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
    Compare:
    The same part on the next line or connector pin is the healthy reading to compare with.
    Watch for:
    A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 1PS79SB17SOD-523Schottky diode, 2 pins, PhilipsSchottky diodeSOD-5232 pinsPhilips
    What it is
    Schottky diode
    Maker
    Philips
    Package
    SOD-523
    Pins
    2
    Details
    Diode: Schottky, Sw, 4V, 30mA, Vf<0.6V(10mA), <0.65pF
    Source
    Published code list

    Is it dead?

    Diode range, part lifted or one leg off the pad. Red probe on the anode.

    Working, it reads

    About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • A reading the wrong way round as well: leaky.
    • Open both ways: failed open.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 2SK242-2SOT-233 pins, Sanyo ElectricNot recordedSOT-233 pinsSanyo Electric
    What it is
    Not recorded
    Maker
    Sanyo Electric
    Package
    SOT-23
    Pins
    3
    Details
    n-FET: AF-Amp, 20V, 20mA, 250mW, Idss=0.6..1,5mA, Ciss=4pF
    Source
    Published code list

    Is it dead?

    Diode range, part lifted. Test drain to source first, then short gate to source and test again.

    Working, it reads

    One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

    Dead, it reads

    • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
    • The gate reads low to source or drain: gate shorted.
    • No body diode at all: failed open.
    On the board
    the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AP8822C-12GASOT-23Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-233 pinsAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 1.2V±2%, -Reset PPO, Rdt=200ms, H-free
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AP8822C-12GTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisorSOT-3233 pinsAnwell Semiconductor
    What it is
    Voltage supervisor
    Maker
    Anwell Semiconductor
    Package
    SOT-323
    Pins
    3
    Details
    Voltage detector IC: 1.2V±2%, -Reset PPO, Rdt=200ms, H-free
    Source
    Published code list

    Is it dead?

    Voltage with the board powered; ohms from each pin to ground with it off.

    Working, it reads

    Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

    Dead, it reads

    • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
    • Supply present, output stuck: failed, or its load has.
    On the board:
    A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
    Compare:
    The surest reference is the same IC on a working board, measured pin by pin.
    Watch for:
    Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • 13 more parts have no package on record
    • BAV20WS-GSwitching diode, Taiwan SemiconductorSwitching diodeNot recordedNot recordedTaiwan Semiconductor
      What it is
      Switching diode
      Maker
      Taiwan Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • Open both ways: failed open.
      • A reading the wrong way round as well: leaky.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESDA07CP30ESD protection diode, LeiditechESD protection diodeNot recordedNot recordedLeiditech
      What it is
      ESD protection diode
      Maker
      Leiditech
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 7 V, Cj 15 pF
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • ESDBLM12VB1ESD protection diode, JSCJESD protection diodeNot recordedNot recordedJSCJ
      What it is
      ESD protection diode
      Maker
      JSCJ
      Package
      Not recorded
      Pins
      Not recorded
      Details
      ESD protection diode, VRWM 12 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • LNP2010DT2AGP-channel MOSFET, LRCP-channel MOSFETNot recordedNot recordedLRC
      What it is
      P-channel MOSFET
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MOSFET, Complementary N&P-Channel, VDSS 20 V, VGS 12 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
      • No body diode at all: failed open.
      On the board
      the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • NTB0102GFLogic level translator, 8 pins, NXPLogic level translatorNot recorded8 pinsNXP
      What it is
      Logic level translator
      Maker
      NXP
      Package
      Not recorded
      Pins
      8
      Details
      1 General description 2 Features and benefits 3 Ordering information
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • NTB0102JKLogic level translator, 8 pins, NXPLogic level translatorNot recorded8 pinsNXP
      What it is
      Logic level translator
      Maker
      NXP
      Package
      Not recorded
      Pins
      8
      Details
      1 General description 2 Features and benefits 3 Ordering information
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • S-LNP2010DT2AGP-channel MOSFET, LRCP-channel MOSFETNot recordedNot recordedLRC
      What it is
      P-channel MOSFET
      Maker
      LRC
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MOSFET, Complementary N&P-Channel, VDSS 20 V, VGS 12 V
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted. Test drain to source first, then short gate to source and test again.

      Working, it reads

      Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

      Dead, it reads

      • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
      • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
      • No body diode at all: failed open.
      On the board
      the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • SN74LVC2T45DCULogic level translator, 8 pins, Texas InstrumentsLogic level translatorNot recorded8 pinsTexas Instruments
      What it is
      Logic level translator
      Maker
      Texas Instruments
      Package
      Not recorded
      Pins
      8
      Details
      Dual-Bit Dual-Supply Bus Transceiver With Configurable Voltage Translation
      Source
      Manufacturer datasheet

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • TST12-521WSchottky diode, Taitron ComponentsSchottky diodeNot recordedNot recordedTaitron Components
      What it is
      Schottky diode
      Maker
      Taitron Components
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Schottky Barrier Diodes (Multiple Terminals)
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, part lifted or one leg off the pad. Red probe on the anode.

      Working, it reads

      About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

      Dead, it reads

      • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
      • A reading the wrong way round as well: leaky.
      • Open both ways: failed open.
      On the board
      this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
      Compare:
      If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
      Watch for:
      A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • VS15VUD1HSESD protection diode, ROHMESD protection diodeNot recordedNot recordedROHM
      What it is
      ESD protection diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient Voltage Suppressor
      Source
      Manufacturer datasheet

      Is it dead?

      Diode range, from the protected line to ground, part lifted if you can.

      Working, it reads

      A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

      Dead, it reads

      • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
      • A reading both ways on a one-way part: leaky.
      • A one-way part open both ways: failed open.
      On the board
      , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
      Compare:
      The same part on the next line or connector pin is the healthy reading to compare with.
      Watch for:
      A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP7341-12FS4-7LDO regulator, Diodes IncorporatedLDO regulatorNot recordedNot recordedDiodes Incorporated
      What it is
      LDO regulator
      Maker
      Diodes Incorporated
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Linear voltage regulator IC: LDO, 1.2V±1%, 300mA, +CE
      Source
      Published code list

      Is it dead?

      Voltage, board powered, black probe on ground. Then ohms with the power off.

      Working, it reads

      Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

      Dead, it reads

      • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
      • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
      • Power off, input to output near 0 Ω: shorted.
      On the board:
      An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
      Compare:
      The same regulator on another rail or another board shows the right voltages and the right resistances.
      Watch for:
      Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP8822C-12GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.2V±2%, -Reset PPO, 200ms Rt delay, H-free
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

    • AP8822C-12GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedNot recordedAnwell Semiconductor
      What it is
      Voltage supervisor
      Maker
      Anwell Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 1.2V±2%, -Reset PPO, 200ms Rt delay, H-free
      Source
      Published code list

      Is it dead?

      Voltage with the board powered; ohms from each pin to ground with it off.

      Working, it reads

      Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

      Dead, it reads

      • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
      • Supply present, output stuck: failed, or its load has.
      On the board:
      A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
      Compare:
      The surest reference is the same IC on a working board, measured pin by pin.
      Watch for:
      Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

      A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

44 more parts are not listed here. Type more of the code to narrow the list.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Download WhatSMD on the App Store
  • Get WhatSMD on Google Play