Skip to content

SMD code search: identify a part by its marking

2 parts are printed Z13C.

2 parts are printed Z13C

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

Zener diode, all SOD-80, 2 pins. What differs:

  • TLZJ13CSOD-80Taitron ComponentsTaitron Components
    What it is
    Zener diode
    Maker
    Taitron Components
    Package
    SOD-80
    Pins
    2
    Details
    SMD Zener Diodes (Leadless ) - 500mW
    Source
    Manufacturer datasheet

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • GLZJ13CSOD-80PanjitPanjit
    What it is
    Zener diode
    Maker
    Panjit
    Package
    SOD-80
    Pins
    2
    Details
    Zener diode: 12.99..13.66V, Zzt=35 , Izt=5mA, 500mW
    Source
    Published code list

    Is it dead?

    Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

    Working, it reads

    About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

    Dead, it reads

    • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
    • Open both ways, forward too: failed open.
    • Holds well off its rated voltage on the supply test: drifted.
    • A soft knee, or a voltage that creeps on the supply test: leaky.
    On the board
    this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

2 more parts have codes that begin with Z13C

Codes that begin with Z13C

For a marking with its end worn or burnt off. Each one shows its full printed code.

Load switch, all Alpha & Omega Semiconductor.

  • AOZ1364AIprinted Z1364AI

    Printed Z1364AI. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Load switch
    Maker
    Alpha & Omega Semiconductor
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Smart load switch
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground.

    Working, it reads

    Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

    Dead, it reads

    • Output at the input voltage while switched off: the pass element has shorted.
    • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
    On the board:
    An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

  • AOZ1364AILprinted Z1364AI

    Printed Z1364AI. Only the start matches what you typed, so this fits only if the rest of the marking is worn off.

    What it is
    Load switch
    Maker
    Alpha & Omega Semiconductor
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Smart load switch
    Source
    Manufacturer datasheet

    Is it dead?

    Voltage, board powered, black probe on ground.

    Working, it reads

    Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

    Dead, it reads

    • Output at the input voltage while switched off: the pass element has shorted.
    • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
    On the board:
    An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
    Compare:
    If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
    Watch for:
    The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

    A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Try Tech free for 30 days. You need a card to start. Unless you cancel during the trial, Tech then costs €12.00 a month plus VAT. See the plans

One code, several parts

Marking codes are not unique. In the standard code book, 6H on a SOT-23 is an NPN transistor, a varicap, an N-channel JFET, two digital transistors, a 3.6 V voltage detector: six parts from five makers. So a search on WhatSMD (What SMD) shows the parts we hold under that code and under codes easily misread as it, with only the columns that tell them apart.

6Hon a SOT-23, in the code book
  • NPN transistor
  • Varicap
  • N-channel JFET
  • Digital transistor ×2
  • 3.6 V voltage detector

When more than one is left

Tap Help me choose. Up to 4 quick answers: whether the part has failed, then what separates the parts left. Those get ranked with the reasoning and a test that settles it. That uses one identification: 2 a month are free without an account, and 3 with a free account.

When you cannot read it

Tap the camera in the field. We read the characters, keep the ones we are unsure of, and search every reading. A photo too soft to read is turned back on your phone first; if it is the only one you can get, you can still send it.

Get the app

The same search on your phone, and a camera with a light, zoom and tap to focus for a marking you cannot read. Sign in with your email address to use the same account.

  • Get WhatSMD on Google Play
  • Coming soon to the App Store