SMD code -AU
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
85 parts are printed -AU
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
2SA2014SOT-893 pins, Sanyo ElectricNot recordedSOT-893 pinsSanyo Electric
- What it is
- Not recorded
- Maker
- Sanyo Electric
- Package
- SOT-89
- Pins
- 3
- Details
- pnp DC cov comp 2SC5567
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SB804-USOT-893 pins, NEC ElectronicsNot recordedSOT-893 pinsNEC Electronics
- What it is
- Not recorded
- Maker
- NEC Electronics
- Package
- SOT-89
- Pins
- 3
- Details
- Si-pnp: AF-Amp, 100V, 1A, 2W, 80MHz, B=200..400
- Source
- Published code list
Is it dead? The meter test is below: This part.
2SB804AUSOT-893 pins, RenesasNot recordedSOT-893 pinsRenesas
- What it is
- Not recorded
- Maker
- Renesas
- Package
- SOT-89
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
74AUP1G158GWSOT-3636 pins, NXPNot recordedSOT-3636 pinsNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- SOT-363
- Pins
- 6
- Details
- CMOS logic IC: 2-input inverting multiplexer
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BAV21WS-GSOD-323Switching diode, 2 pins, VishaySwitching diodeSOD-3232 pinsVishay
- What it is
- Switching diode
- Maker
- Vishay
- Package
- SOD-323
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
BCW60GRSOT-233 pins, Ferranti SemiconductorsNot recordedSOT-233 pinsFerranti Semiconductors
- What it is
- Not recorded
- Maker
- Ferranti Semiconductors
- Package
- SOT-23
- Pins
- 3
- Details
- BCY58
- Source
- Published code list
Is it dead? The meter test is below: This part.
BCX70GRSOT-233 pins, InfineonNot recordedSOT-233 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: AF, 45V, 200mA, 330mW, B=120..220, >250MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
BCX70RGSOT-233 pins, InfineonNot recordedSOT-233 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- Si-npn: GP, 45V, 100mA, 330mW, B= 120..220, 250MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
BFP540ESDSOT-3434 pins, InfineonNot recordedSOT-3434 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOT-343
- Pins
- 4
- Details
- npn microwave fT 30GHz ESD protected BFP540
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
6 more parts have no package on record
7WB3126AMXonsemiNot recordedNot recordedNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-Bit bus switch
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
7WB3126BMXonsemiNot recordedNot recordedNot recordedonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-Bit bus switch
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP1G158GFNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-input inverting multiplexer
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP1G158GMNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-input inverting multiplexer
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP1G158GNNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-input inverting multiplexer
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
74AUP1G158GSNXPNot recordedNot recordedNot recordedNXP
- What it is
- Not recorded
- Maker
- NXP
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS logic IC: 2-input inverting multiplexer
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.