Skip to content

SMD code -K9

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

69 parts are printed -K9

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • BB199SOD-523Varicap diode, 2 pins, NXPVaricap diodeSOD-5232 pinsNXP
    What it is
    Varicap diode
    Maker
    NXP
    Package
    SOD-523
    Pins
    2
    Details
    Variable capacitance diode for VCO and VCXO
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: PIN diode or varicap.

  • BZD17C56PSOD-123FZener diode, 2 pins, VishayZener diodeSOD-123F2 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123F
    Pins
    2
    Details
    56 V Zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZD27C22PSOD-123FTVS diode, 2 pins, Galaxy MicroelectronicsTVS diodeSOD-123F2 pinsGalaxy Microelectronics
    What it is
    TVS diode
    Maker
    Galaxy Microelectronics
    Package
    SOD-123F
    Pins
    2
    Details
    18V, 150W, Surface Mount TVS
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • BZX7B5V1SOD-723Zener diode, 2 pins, Good-ArkZener diodeSOD-7232 pinsGood-Ark
    What it is
    Zener diode
    Maker
    Good-Ark
    Package
    SOD-723
    Pins
    2
    Details
    Zener diode, VZ 5.1 V, 0.1 W
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84-C20,215SOT-23Zener diode, 3 pins, HXYZener diodeSOT-233 pinsHXY
    What it is
    Zener diode
    Maker
    HXY
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, 75 V, 0.05 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84C20SOT-23Zener diode, 3 pins, DiotecZener diodeSOT-233 pinsDiotec
    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84C20-Q1SOT-23Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-233 pinsFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX384-B5V1SOD-323Zener diode, 2 pins, NexperiaZener diodeSOD-3232 pinsNexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX384B12SOD-323Zener diode, 2 pins, VishayZener diodeSOD-3232 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-323
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • CHSD05JSGP-ASOD-123Schottky diode, 2 pins, ChenmkoSchottky diodeSOD-1232 pinsChenmko
    What it is
    Schottky diode
    Maker
    Chenmko
    Package
    SOD-123
    Pins
    2
    Details
    SCHOTTKY BARRIER RECTIFIER, 100 V, 0.5 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • EM5213AVA-30DFNLoad switch, Excelliance MOSLoad switchDFNNot recordedExcelliance MOS
    What it is
    Load switch
    Maker
    Excelliance MOS
    Package
    DFN
    Pins
    Not recorded
    Details
    Power switch
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Load switch.

  • MMSZ5249BSOD-123FZener diode, 2 pins, DiotecZener diodeSOD-123F2 pinsDiotec
    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOD-123F
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MMSZ5254SOD-123Zener diode, 2 pins, VishayZener diodeSOD-1232 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    27 V Zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • MMSZ5254-GSOD-123Zener diode, 2 pins, VishayZener diodeSOD-1232 pinsVishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SOD-123
    Pins
    2
    Details
    27 V Zener diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • 1 more part has no package on record
    • BFCN-3700+RF filter, Mini-CircuitsRF filterNot recordedNot recordedMini-Circuits
      What it is
      RF filter
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      LTCC filter, 3000-4600 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as -K9

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with -K9

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 1 more part.

Did you find your part?

Open this in the search to correct a character or try another package.