Skip to content

SMD code 1020

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

1020 on a chip resistor

102 Ω

102 Ω resistor, 1%

102 followed by 0 zeros. Four digits is normally the 1% series.

Check it with a meter

Lift one end and measure across it. A good one reads 102 Ω within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 102 Ω on the board is a fault. Open, or well above 102 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 102 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (USP-6B, QFN, SMA), 1020 is a part code instead. Those parts are listed below.

2 parts are printed 1020

Not sure which one you have?

Answer up to 4 quick questions and these 2 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • SZ1020SMAZener diode, 2 pins, EIC SemiconductorZener diodeSMA2 pinsEIC Semiconductor
    What it is
    Zener diode
    Maker
    EIC Semiconductor
    Package
    SMA
    Pins
    2
    Details
    Zener diode: 20V±10%, Zzt=22, Izt=45mA, 1W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 1 more part has no package on record
    • PMA3-10203+RF amplifier (MMIC), Mini-CircuitsRF amplifier (MMIC)Not recordedNot recordedMini-Circuits
      What it is
      RF amplifier (MMIC)
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MMIC amplifier, 12.5-20 GHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: RF amplifier.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

RF amplifier

Voltage, board powered, on the output pin that the bias resistor or choke feeds.

Working, it reads

The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

Dead, it reads

  • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
  • Output pin at the full supply voltage: open inside, no current flowing.
On the board:
Measured on the board with power on; the bias network is part of the reading.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The figures depend on the part and its bias resistor. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 1020

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.