SMD code 2Cs in SOT-23
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, s, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and 2C was searched.
12 parts in SOT-23 are printed 2Cs
Not sure which one you have?
Answer up to 4 quick questions and these 47 parts are ranked, with a meter test that settles it. It works on a dead part too.
849CSOT-23Transistor, 3 pins, YFWTransistor3 pinsYFW
- What it is
- Transistor
- Maker
- YFW
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
BC849CSOT-23Transistor, 3 pins, InfineonTransistor3 pinsInfineon
- What it is
- Transistor
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- SMD General Purpose NPN Transistors
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
BC849CLSOT-23NPN transistor, 3 pins, onsemiNPN transistor3 pinsonsemi
- What it is
- NPN transistor
- Maker
- onsemi
- Package
- SOT-23
- Pins
- 3
- Details
- General Purpose Transistors Series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
TZT2.4WSOT-23Zener diode, 3 pins, Taitron ComponentsZener diode3 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SOT-23
- Pins
- 3
- Details
- SMD Zener Diodes (Three Terminals) - 200mW
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
AD1582SOT-233 pins, Analog DevicesNot recorded3 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-23
- Pins
- 3
- Details
- 2.50 V Precision Series Mode Voltage References
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
FMMT-A70SOT-233 pins, Diodes IncorporatedNot recorded3 pinsDiodes Incorporated
- What it is
- Not recorded
- Maker
- Diodes Incorporated
- Package
- SOT-23
- Pins
- 3
- Details
- equivalent MPSA70
- Source
- Published code list
Is it dead? The meter test is below: This part.
FMMT4124SOT-233 pins, SK TechnologyNot recorded3 pinsSK Technology
- What it is
- Not recorded
- Maker
- SK Technology
- Package
- SOT-23
- Pins
- 3
- Details
- 2N4124
- Source
- Published code list
Is it dead? The meter test is below: This part.
MMBTA70SOT-233 pins, Texas InstrumentsNot recorded3 pinsTexas Instruments
- What it is
- Not recorded
- Maker
- Texas Instruments
- Package
- SOT-23
- Pins
- 3
- Details
- Si-pnp: GP, 40V, 100mA, 225mW, B=40..400, >125MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
R3131N32ECSOT-233 pins, Nisshinbo Micro DevicesNot recorded3 pinsNisshinbo Micro Devices
- What it is
- Not recorded
- Maker
- Nisshinbo Micro Devices
- Package
- SOT-23
- Pins
- 3
- Details
- CMOS-IC: Voltage Detector 3.2V, Reset Open drain output, 240ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
SMBTA70SOT-23PNP transistor, 3 pins, InfineonPNP transistor3 pinsInfineon
- What it is
- PNP transistor
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- Si-pnp: GP, 40V, 100mA, 350mW, B=40..100, >125MHz
- Source
- Published code list
Is it dead? The meter test is below: PNP transistor.
TMPTA70SOT-233 pins, AllNot recorded3 pinsAll
- What it is
- Not recorded
- Maker
- All
- Package
- SOT-23
- Pins
- 3
- Details
- Si-pnp: GP, 40V, 100mA, 350mW, B=40..100, >125MHz
- Source
- Published code list
Is it dead? The meter test is below: This part.
Z02W2.4VSOT-23Zener diode, 3 pins, KECZener diode3 pinsKEC
- What it is
- Zener diode
- Maker
- KEC
- Package
- SOT-23
- Pins
- 3
- Details
- Z-diode: 2.28..2.60V, Izt=5mA, Zzt=100Ω, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
3 more parts have no package on record. Nothing rules them out, so they stay.
G2262-15AU1UDC-DC converter, 6 pins, Global Mixed-mode TechnologyDC-DC converter6 pinsGlobal Mixed-mode Technology
- What it is
- DC-DC converter
- Maker
- Global Mixed-mode Technology
- Package
- Not recorded
- Pins
- 6
- Details
- 2A, 1.6MHz, COT Synchronous Step-Down Converter
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
GBLC12CDNESD protection diode, ProTek DevicesESD protection diodeNot recordedProTek Devices
- What it is
- ESD protection diode
- Maker
- ProTek Devices
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Ultra Low Capacitance TVS
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
L12BT1006AESD protection diode, Formosa MicrosemiESD protection diodeNot recordedFormosa Microsemi
- What it is
- ESD protection diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 2Cs
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 194 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.