SMD code 2H
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.
7 parts are printed 2H
Not sure which one you have?
Answer up to 4 quick questions and these 7 parts are ranked, with a meter test that settles it. It works on a dead part too.
BZD27B200PSOD-123FZener diode, 2 pins, VishayZener diodeSOD-123F2 pinsVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SOD-123F
- Pins
- 2
- Details
- 200 V Zener diode
- Source
- From the manufacturer's datasheet
Is it dead? The meter test is below: Zener diode.
MM3Z16SOD-323Zener diode, 2 pins, DiotecZener diodeSOD-3232 pinsDiotec
- What it is
- Zener diode
- Maker
- Diotec
- Package
- SOD-323
- Pins
- 2
- Details
- SMD Planar Zener Diodes
- Source
- From the manufacturer's datasheet
Is it dead? The meter test is below: Zener diode.
MMBTA55SOT-23PNP transistor, 3 pins, JSCJPNP transistorSOT-233 pinsJSCJ
- What it is
- PNP transistor
- Maker
- JSCJ
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, PNP
- Source
- From the manufacturer's datasheet
Is it dead? The meter test is below: PNP transistor.
PBSS5140TSOT-23PNP transistor, 3 pins, NexperiaPNP transistorSOT-233 pinsNexperia
- What it is
- PNP transistor
- Maker
- Nexperia
- Package
- SOT-23
- Pins
- 3
- Details
- 40 V, 1 A PNP low VCEsat transistor
- Source
- From the manufacturer's datasheet
Is it dead? The meter test is below: PNP transistor.
PUMH2SOT-363Digital transistor (NPN, resistors built in), 6 pins, NexperiaDigital transistor (NPN, resistors built in)SOT-3636 pinsNexperia
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- Nexperia
- Package
- SOT-363
- Pins
- 6
- Details
- 50 V, 100 mA NPN/NPN resistor-equipped double transistor; R1 = 47 kΩ, R2 = 47 kΩ
- Source
- From the manufacturer's datasheet
Is it dead? The meter test is below: Digital transistor.
TL432BIPKSOT-89Voltage reference, 3 pins, Texas InstrumentsVoltage referenceSOT-893 pinsTexas Instruments
- What it is
- Voltage reference
- Maker
- Texas Instruments
- Package
- SOT-89
- Pins
- 3
- Details
- Precision Programmable Reference
- Source
- From the manufacturer's datasheet
Is it dead? The meter test is below: Integrated circuit.
1 more part has no package on record
VESD16C1-HD1ESD protection diode, VishayESD protection diodeNot recordedNot recordedVishay
- What it is
- ESD protection diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Single-Line ESD-Protection Diode in DFN1006-2A
- Source
- From the manufacturer's datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 2H
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with 2H
For a marking with its end worn or burnt off. Each code has a page of its own.
Open this in the search to correct a character or try another package.