SMD code 2Lp
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and 2L was searched.
94 parts are printed 2Lp
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
2N5401SSOT-23PNP transistor, 3 pins, HXYPNP transistorSOT-233 pinsHXY
- What it is
- PNP transistor
- Maker
- HXY
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, 150 V, 0.6 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
2N5401S-RTK/PSOT-23PNP transistor, 3 pins, HXYPNP transistorSOT-233 pinsHXY
- What it is
- PNP transistor
- Maker
- HXY
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, 150 V, 0.6 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
AMMBT5401-HFSOT-23PNP transistor, 3 pins, ComchipPNP transistorSOT-233 pinsComchip
- What it is
- PNP transistor
- Maker
- Comchip
- Package
- SOT-23
- Pins
- 3
- Details
- -150 V, -0.6 A PNP transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
BF1208SOT-563N-channel MOSFET, 6 pins, NXPN-channel MOSFETSOT-5636 pinsNXP
- What it is
- N-channel MOSFET
- Maker
- NXP
- Package
- SOT-563
- Pins
- 6
- Details
- Dual N-channel dual gate MOSFET
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
ESD3Z20CSOD-323ESD protection diode, 2 pins, YFWESD protection diodeSOD-3232 pinsYFW
- What it is
- ESD protection diode
- Maker
- YFW
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
FMBT5401SOT-23PNP transistor, 3 pins, Formosa MicrosemiPNP transistorSOT-233 pinsFormosa Microsemi
- What it is
- PNP transistor
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
FMBT5401-Q1SOT-23PNP transistor, 3 pins, Formosa MicrosemiPNP transistorSOT-233 pinsFormosa Microsemi
- What it is
- PNP transistor
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
FMBT5401DW1SOT-363Dual PNP transistor, 6 pins, Formosa MicrosemiDual PNP transistorSOT-3636 pinsFormosa Microsemi
- What it is
- Dual PNP transistor
- Maker
- Formosa Microsemi
- Package
- SOT-363
- Pins
- 6
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor pair.
GSMMBT5401SOT-23PNP transistor, 3 pins, Good-ArkPNP transistorSOT-233 pinsGood-Ark
- What it is
- PNP transistor
- Maker
- Good-Ark
- Package
- SOT-23
- Pins
- 3
- Details
- PNP transistor, 150 V, 0.6 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
HMMBT5401TSOT-523PNP transistor, 3 pins, HXYPNP transistorSOT-5233 pinsHXY
- What it is
- PNP transistor
- Maker
- HXY
- Package
- SOT-523
- Pins
- 3
- Details
- Bipolar transistor, 150 V, 0.6 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
LMBT5401DW1T1GSOT-363Transistor, 6 pins, LRCTransistorSOT-3636 pinsLRC
- What it is
- Transistor
- Maker
- LRC
- Package
- SOT-363
- Pins
- 6
- Details
- Bipolar transistor, P+P, IC 500 mA, VCEO 150 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
LMBT5401LT1GSOT-23PNP transistor, 3 pins, LRCPNP transistorSOT-233 pinsLRC
- What it is
- PNP transistor
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor, PNP, IC 500 mA, VCEO 150 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PNP transistor.
3 more parts have no package on record
FM2L45-MSSchottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Schottky diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
FM2L45-MS-Q1Schottky diode, Formosa MicrosemiSchottky diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Schottky diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LL05BT1006D-Q1ESD protection diode, Formosa MicrosemiESD protection diodeNot recordedNot recordedFormosa Microsemi
- What it is
- ESD protection diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
PNP transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PNP transistor pair
Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.
Working, it reads
Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 2Lp
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 48 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.