Skip to content

SMD code 304P

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

304P on a chip capacitor

304 pF

304 pF capacitor

The p is both the decimal point and the unit: 304 pF.

Check it with a meter

Lift one end and measure it on a capacitance range. A good one reads close to 304 pF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. A failed one usually reads near 0 Ω, or a steady low resistance, on the ohms range, often from a crack. On the board a shorted capacitor shorts its whole rail. A failed reading does not change what to fit: the marking still says 304 pF.

On a transistor or diode body (SOT-23), 304P is a part code instead. Those parts are listed below.

The only part printed 304P in our tables

FDN304P

What it is
P-channel MOSFET
Maker
onsemi
Package
SOT-23
Pins
3
Details
P-channel MOSFET, 20 V, 5 A
Source
Manufacturer datasheet

Is it dead?

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Datasheetfor FDN304P, opens in a new tab

Was it this one?

Did you find your part?

Open this in the search to correct a character or try another package.