Skip to content

SMD code 323 in SOT-23-6

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

4 parts in SOT-23-6 are printed 323

Not sure which one you have?

Answer up to 4 quick questions and these 6 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • TPP302083-T6TRSOT-23-6DC-DC converter, 3PEAKDC-DC converter3PEAK
    What it is
    DC-DC converter
    Maker
    3PEAK
    Package
    SOT-23-6
    Pins
    6
    Details
    30-V Input, 2-A Synchronous Step-Down Voltage Regulator
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • TPP362083-T6TRSOT-23-6DC-DC converter, 3PEAKDC-DC converter3PEAK
    What it is
    DC-DC converter
    Maker
    3PEAK
    Package
    SOT-23-6
    Pins
    6
    Details
    36-V Input, 2-A Synchronous Step-Down Voltage Regulator
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • ADA4432-1WBRJZ-R7SOT-23-6Analog DevicesNot recordedAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    SOT-23-6
    Pins
    6
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • FDC6323LSOT-23-6onsemiNot recordedonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-23-6
    Pins
    6
    Details
    Load switch
    Source
    Published code list

    Is it dead? The meter test is below: Load switch.

  • 2 more parts have no package on record. Nothing rules them out, so they stay.
    • FDMA3023PZDual P-channel MOSFET, onsemiDual P-channel MOSFETonsemi
      What it is
      Dual P-channel MOSFET
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      MOSFET - Dual, P-Channel, POWERTRENCH
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: P-channel MOSFET pair.

    • TCK323GLoad switch, ToshibaLoad switchToshiba
      What it is
      Load switch
      Maker
      Toshiba
      Package
      Not recorded
      Pins
      Not recorded
      Details
      36 V, Dual Inputs - Single Output Power Multiplexer IC with Over Voltage Protection
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Load switch.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Load switch

Voltage, board powered, black probe on ground.

Working, it reads

Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.

Dead, it reads

  • Output at the input voltage while switched off: the pass element has shorted.
  • Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
On the board:
An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

P-channel MOSFET pair

Diode range, part lifted. Test drain to source first, then short gate to source and test again. Test each MOSFET on its own pins, as the datasheet's pinout gives them.

Working, it reads

Red probe on the drain, black on the source: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 323

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with 323

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.