SMD code 35-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
105 parts are printed 35-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
ET3175DFNLoad switch, ETEKLoad switchDFNNot recordedETEK
- What it is
- Load switch
- Maker
- ETEK
- Package
- DFN
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
FMUN5335DW1SOT-363Digital transistor (resistors built in), 6 pins, Formosa MicrosemiDigital transistor (resistors built in)SOT-3636 pinsFormosa Microsemi
- What it is
- Digital transistor (resistors built in)
- Maker
- Formosa Microsemi
- Package
- SOT-363
- Pins
- 6
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
HBCA123JS6RSOT-363Complementary transistor pair (NPN and PNP), 6 pins, CYStekComplementary transistor pair (NPN and PNP)SOT-3636 pinsCYStek
- What it is
- Complementary transistor pair (NPN and PNP)
- Maker
- CYStek
- Package
- SOT-363
- Pins
- 6
- Details
- NPN+PNP digital (resistor-equipped) transistor, R1 2.2K/2.2K, R2 47K/47K
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor pair.
LBZT52B13T1GSOD-123Zener diode, 2 pins, LRCZener diodeSOD-1232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, VZ Min 12.91 V, VZ Nom 13.2 V, VZ Max 13.49 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LBZX84B13LT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 12.91 V, VZ Nom 13.2 V, VZ Max 13.49 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LEDZ13BPT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 12.91 V, VZ Nom 13.2 V, VZ Max 13.49 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LEDZ13BT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 12.91 V, VZ Nom 13.2 V, VZ Max 13.49 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LMBR350FT1GSOD-123FSchottky diode, 2 pins, LRCSchottky diodeSOD-123F2 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-123F
- Pins
- 2
- Details
- Schottky diode, VR 50 V, IF 3 A, VF Max 0.7 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LMUN5335DW1T1GSOT-363Digital transistor (resistors built in), 6 pins, LRCDigital transistor (resistors built in)SOT-3636 pinsLRC
- What it is
- Digital transistor (resistors built in)
- Maker
- LRC
- Package
- SOT-363
- Pins
- 6
- Details
- Digital transistor (bias resistors built in), P+N, IC 100 mA, VCEO 50 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
LUDZS13BT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Zener diode, VZ Min 12.91 V, VZ Nom 13.2 V, VZ Max 13.49 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MBRX350SOD-123FSchottky diode, 2 pins, Galaxy MicroelectronicsSchottky diodeSOD-123F2 pinsGalaxy Microelectronics
- What it is
- Schottky diode
- Maker
- Galaxy Microelectronics
- Package
- SOD-123F
- Pins
- 2
- Details
- 3A, 50V, Surface Mount Schottky Barrier Rectifiers
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
4 more parts have no package on record
FDG6335NN-channel MOSFET, onsemiN-channel MOSFETNot recordedNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- MOSFET - N-Channel, POWERTRENCH
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
MM5Z3V3BZener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MM5Z3V3B-Q1Zener diode, Formosa MicrosemiZener diodeNot recordedNot recordedFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
RB050L-40DDSchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor pair
Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.