Skip to content

SMD code 39

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

3 parts are printed 39

Not sure which one you have?

Answer up to 4 quick questions and these 3 parts are ranked, with a meter test that settles it. It works on a dead part too.

2 pins. What differs:

  • BZX384-A22SOD-323Zener diode, Nexperia
    What it is
    Zener diode
    Maker
    Nexperia
    Package
    SOD-323
    Pins
    2
    Source
    From the manufacturer's datasheet

    Is it dead? The meter test is below: Zener diode.

  • SML4754SMAZener diode, Vishay
    What it is
    Zener diode
    Maker
    Vishay
    Package
    SMA
    Pins
    2
    Details
    39 V Zener diode
    Source
    From the manufacturer's datasheet

    Is it dead? The meter test is below: Zener diode.

  • EIA-96:390603Precision resistor (EIA-96 code)
    What it is
    Precision resistor (EIA-96 code)
    Maker
    Not recorded
    Package
    0603
    Pins
    2
    Details
    EIA-96 precision chip resistor, significand 24.9; the printed mark adds a multiplier letter (39A = 249 Ohm, 39B = 2.49 kOhm)
    Source
    Added by hand from a published table

    Is it dead? The meter test is below: Resistor.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Resistor

Ohms range, across it, power off.

Working, it reads

Its marked value, within tolerance. On the board it reads the same or lower, because everything around it sits in parallel.

Dead, it reads

  • Open: burnt, cracked, or eaten through by sulphur. The commonest failure.
  • Well above its marked value: drifted high.
  • On the board, clearly higher than its marked value: it has failed, since the board can only pull a reading down.
On the board:
A reading lower than marked on the board proves nothing; lift one end. A reading higher than marked is a fault even on the board.
Compare:
The same position on another channel usually carries the same value, and so does the matching part on another board.
Watch for:
A burnt resistor usually means the part it feeds pulled too much. Find that before fitting a new one, or it burns too. The marking, not the reading, says what to fit.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes that begin with 39

For a marking with its end worn or burnt off. Each code has a page of its own.

Open this in the search to correct a character or try another package.