SMD code 43B
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
43B on a chip resistor
2.74 kΩ
2.74 kΩ resistor, 1%
EIA-96 precision code: 43 stands for 274 in the E96 table, and the letter B is the multiplier, × 10. These are 1% parts.
Check it with a meter
Lift one end and measure across it. A good one reads 2.74 kΩ within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 2.74 kΩ on the board is a fault. Open, or well above 2.74 kΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 2.74 kΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.
On a transistor or diode body (SOT-23, SOT-23-5, SMB), 43B is a part code instead. Those parts are listed below.
22 parts are printed 43B
Not sure which one you have?
Answer up to 4 quick questions and these 22 parts are ranked, with a meter test that settles it. It works on a dead part too.
1SMB3EZ43SMBZener diode, 2 pins, PanjitZener diodeSMB2 pinsPanjit
- What it is
- Zener diode
- Maker
- Panjit
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CHBZ43BGPSOT-23Zener diode, 3 pins, ChenmkoZener diodeSOT-233 pinsChenmko
- What it is
- Zener diode
- Maker
- Chenmko
- Package
- SOT-23
- Pins
- 3
- Details
- DUAL SILICON PLANAR POWER ZENER DIODES, 2.4 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
KIA431BMSOT-23LDO regulator, 3 pins, KECLDO regulatorSOT-233 pinsKEC
- What it is
- LDO regulator
- Maker
- KEC
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
SMAZ5943BSMAZener diode, 2 pins, VishayZener diodeSMA2 pinsVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SMA
- Pins
- 2
- Details
- 56 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
SMBZ5943BSMBZener diode, 2 pins, VishayZener diodeSMB2 pinsVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- SMB
- Pins
- 2
- Details
- 56 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
Z3SMB43BSMBZener diode, 2 pins, Taitron ComponentsZener diodeSMB2 pinsTaitron Components
- What it is
- Zener diode
- Maker
- Taitron Components
- Package
- SMB
- Pins
- 2
- Details
- SMD Zener Diodes (Two Terminals)- 3W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
1SMA5943BSMAZener diode, 2 pins, RectronZener diodeSMA2 pinsRectron
- What it is
- Zener diode
- Maker
- Rectron
- Package
- SMA
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
AAT60043B-S2SOT-23Voltage supervisor, 3 pins, Advanced Analog TechnologyVoltage supervisorSOT-233 pinsAdvanced Analog Technology
- What it is
- Voltage supervisor
- Maker
- Advanced Analog Technology
- Package
- SOT-23
- Pins
- 3
- Details
- Voltage detector IC: 4.3V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AAT60043B-S5SOT-23-5Voltage supervisor, 5 pins, Advanced Analog TechnologyVoltage supervisorSOT-23-55 pinsAdvanced Analog Technology
- What it is
- Voltage supervisor
- Maker
- Advanced Analog Technology
- Package
- SOT-23-5
- Pins
- 5
- Details
- Voltage detector IC: 4.3V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AAT60043B-S15SOT-143Voltage supervisor, 4 pins, Advanced Analog TechnologyVoltage supervisorSOT-1434 pinsAdvanced Analog Technology
- What it is
- Voltage supervisor
- Maker
- Advanced Analog Technology
- Package
- SOT-143
- Pins
- 4
- Details
- Voltage detector IC: 4.3V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AAT60043B-S16SOT-89Voltage supervisor, 3 pins, Advanced Analog TechnologyVoltage supervisorSOT-893 pinsAdvanced Analog Technology
- What it is
- Voltage supervisor
- Maker
- Advanced Analog Technology
- Package
- SOT-89
- Pins
- 3
- Details
- Voltage detector IC: 4.3V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
LN1152B122MRSOT-23-5LDO regulator, 5 pins, Shanghai Natlinear ElectronicsLDO regulatorSOT-23-55 pinsShanghai Natlinear Electronics
- What it is
- LDO regulator
- Maker
- Shanghai Natlinear Electronics
- Package
- SOT-23-5
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 1.2V±2%, 100mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
3 more parts have no package on record
1SMB3EZ43-AUZener diode, PanjitZener diodeNot recordedNot recordedPanjit
- What it is
- Zener diode
- Maker
- Panjit
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
KA431SAMFTFVoltage reference, onsemiVoltage referenceNot recordedNot recordedonsemi
- What it is
- Voltage reference
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Programmable Shunt Regulator
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
KA431SAMFFairchild SemiconductorNot recordedNot recordedNot recordedFairchild Semiconductor
- What it is
- Not recorded
- Maker
- Fairchild Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Parallel stabilizer
- Source
- Published code list
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 43B
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes that begin with 43B
For a marking with its end worn or burnt off. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.