Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
171 parts are printed 5-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
LBZT52B10T1GSOD-123Zener diode, 2 pins, LRCZener diodeSOD-1232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-123
- Pins
- 2
- Details
- Zener diode, VZ Min 9.77 V, VZ Nom 10 V, VZ Max 10.21 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LBZX84B10LT1GSOT-23Zener diode, 3 pins, LRCZener diodeSOT-233 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOT-23
- Pins
- 3
- Details
- Zener diode, VZ Min 9.77 V, VZ Nom 10 V, VZ Max 10.21 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LEDZ10BPT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 9.77 V, VZ Nom 10 V, VZ Max 10.21 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LEDZ10BT1GSOD-523Zener diode, 2 pins, LRCZener diodeSOD-5232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Zener diode, VZ Min 9.77 V, VZ Nom 10 V, VZ Max 10.21 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LM3Z3V3T1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Zener diode, VZ Min 3.1 V, VZ Nom 3.3 V, VZ Max 3.5 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LNZ8F5V6T5GSOD-882Zener diode, 2 pins, LRCZener diodeSOD-8822 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-882
- Pins
- 2
- Details
- Zener diode, VZ Min 5.32 V, VZ Nom 5.6 V, VZ Max 5.88 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LNZ9F5V6T5GSOD-923Zener diode, 2 pins, LRCZener diodeSOD-9232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-923
- Pins
- 2
- Details
- Zener diode, VZ Min 5.32 V, VZ Nom 5.6 V, VZ Max 5.88 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
LRB500V-40T1GSOD-323Schottky diode, 2 pins, LRCSchottky diodeSOD-3232 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Schottky diode, VR 40 V, IF 0.1 A, VF Max 0.45 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LRB751BS-40T5GSOD-882Schottky diode, 2 pins, LRCSchottky diodeSOD-8822 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-882
- Pins
- 2
- Details
- Schottky diode, VR 30 V, IF 0.03 A, VF Max 0.37 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LRB751CS-40T5GSOD-923Schottky diode, 2 pins, LRCSchottky diodeSOD-9232 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-923
- Pins
- 2
- Details
- Schottky diode, VR 30 V, IF 0.03 A, VF Max 0.37 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LRB751G-40T1GSOD-723Schottky diode, 2 pins, LRCSchottky diodeSOD-7232 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-723
- Pins
- 2
- Details
- Schottky diode, VR 30 V, IF 0.03 A, VF Max 0.37 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LRB751S-40T1GSOD-523Schottky diode, 2 pins, LRCSchottky diodeSOD-5232 pinsLRC
- What it is
- Schottky diode
- Maker
- LRC
- Package
- SOD-523
- Pins
- 2
- Details
- Schottky diode, VR 40 V, IF 0.03 A, VF Max 0.37 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LUDZS10BT1GSOD-323Zener diode, 2 pins, LRCZener diodeSOD-3232 pinsLRC
- What it is
- Zener diode
- Maker
- LRC
- Package
- SOD-323
- Pins
- 2
- Details
- Zener diode, VZ Min 9.77 V, VZ Nom 10 V, VZ Max 10.21 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
2 more parts have no package on record
GSRB751D-40Schottky diode, Good-ArkSchottky diodeNot recordedNot recordedGood-Ark
- What it is
- Schottky diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky diode, 30 V, 30 mA
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
LESD11D5.0ET5GESD protection diode, LRCESD protection diodeNot recordedNot recordedLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- ESD protection diode, VRWM 5 V, IR @VRWM 0.5 μA, VBR Min 5.6 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.