Skip to content

SMD code 505

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

5 parts are printed 505

Not sure which one you have?

Answer up to 4 quick questions and these 5 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ACGRC505-HFSMCRectifier, 2 pins, ComchipRectifierSMC2 pinsComchip
    What it is
    Rectifier
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    600 V, 5 A rectifier
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Silicon diode.

  • LN3526N5012MSOT-143Voltage supervisor, 4 pins, Shanghai Natlinear ElectronicsVoltage supervisorSOT-1434 pinsShanghai Natlinear Electronics
    What it is
    Voltage supervisor
    Maker
    Shanghai Natlinear Electronics
    Package
    SOT-143
    Pins
    4
    Details
    Voltage detector IC: 5.0V±2%, -Reset ODO, -MR, 200ms Rt delay
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • R1191N105BSOT-23-5LDO regulator, 5 pins, RicohLDO regulatorSOT-23-55 pinsRicoh
    What it is
    LDO regulator
    Maker
    Ricoh
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, 10.5V±1.5%, 300mA, +CE, ECO
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • S505TSOT-143RF amplifier (MMIC), 4 pins, VishayRF amplifier (MMIC)SOT-1434 pinsVishay
    What it is
    RF amplifier (MMIC)
    Maker
    Vishay
    Package
    SOT-143
    Pins
    4
    Details
    biased dg mosfet MOSIC 5V uhf tv tuners
    Source
    Published code list

    Is it dead? The meter test is below: RF amplifier.

  • SST505SOT-233 pins, CalogicNot recordedSOT-233 pinsCalogic
    What it is
    Not recorded
    Maker
    Calogic
    Package
    SOT-23
    Pins
    3
    Details
    Current regulator diode
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

RF amplifier

Voltage, board powered, on the output pin that the bias resistor or choke feeds.

Working, it reads

The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.

Dead, it reads

  • Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
  • Output pin at the full supply voltage: open inside, no current flowing.
On the board:
Measured on the board with power on; the bias network is part of the reading.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The figures depend on the part and its bias resistor. The datasheet gives both.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 505

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.