5100 on a chip resistor

510 Ω

510 Ω resistor, 1%

510 followed by 0 zeros. Four digits is normally the 1% series.

Check it with a meter

Lift one end and measure across it. A good one reads 510 Ω within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 510 Ω on the board is a fault. Open, or well above 510 Ω, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 510 Ω. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SOT-23, SOT-23-5, SMA), 5100 is a part code instead. Those parts are listed below.

4 parts are printed 5100

Not sure which one you have?

Answer up to 4 quick questions and these 4 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ACDBC5100-HFSMCSchottky diode, 2 pins, ComchipSchottky diodeSMC2 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    100 V, 5 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • CDBC5100-HFSMCSchottky diode, 2 pins, ComchipSchottky diodeSMC2 pinsComchip
    What it is
    Schottky diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    100 V, 5 A Schottky barrier diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • LTC5100EUFQFN16 pins, Analog DevicesNot recordedQFN16 pinsAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    QFN
    Pins
    16
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • S5KP100D2PAKTVS diode, 3 pins, EIC SemiconductorTVS diodeD2PAK3 pinsEIC Semiconductor
    What it is
    TVS diode
    Maker
    EIC Semiconductor
    Package
    D2PAK
    Pins
    3
    Details
    Transient voltage supressor: Vbr=111..136V, Vrwm=100V, 28A, 5000W(1ms)
    Source
    Published code list

    Is it dead? The meter test is below: TVS or ESD protection diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 5100

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with 5100

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.