Skip to content

SMD marking

564A

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables.

564A on a chip capacitor

560 nF, 10 V

560 nF, 10 V tantalum capacitor

A moulded tantalum capacitor: 564 is the capacitance in picofarads (560 nF) and A is the rated-voltage code (10 V).

Check it with a meter

Lift one end and measure it on a capacitance range. A good one reads close to 560 nF. In circuit the meter also sees everything connected across it, so the reading means little until it is out. It is polarised: the band on the body marks the positive end, and a tantalum fitted backwards fails short, sometimes with a flame. A failed tantalum usually reads near 0 Ω both ways, often with a burnt or cracked body. A failed reading does not change what to fit: the marking still says 560 nF, 10 V. Fit the same capacitance at the same or a higher voltage.

On a transistor or diode body, 564A is a part code instead. Those parts are listed below.

The only part printed 564A in our tables

PJQ4564AP-AU

What it is
MOSFET
Maker
Panjit
Package
Not recorded
Pins
Not recorded
Source
From the manufacturer's datasheet

Is it dead?

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

One way between drain and source reads about 0.4 to 0.9 V, the body diode, and the other way open. The gate reads open to both other pins.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted.
  • No body diode at all: failed open.
On the board:
On the board the gate usually has a resistor to the source, which reads as that resistor and is not a fault. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.