SMD code 5Fc
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, c, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and 5F was searched.
112 parts are printed 5Fc
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
BC808–25WT1SOT-3233 pins, onsemiNot recordedSOT-3233 pinsonsemi
- What it is
- Not recorded
- Maker
- onsemi
- Package
- SOT-323
- Pins
- 3
- Source
- Published code list
Is it dead? The meter test is below: This part.
BZX584C10SOD-523Zener diode, 2 pins, RectronZener diodeSOD-5232 pinsRectron
- What it is
- Zener diode
- Maker
- Rectron
- Package
- SOD-523
- Pins
- 2
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
FSS115SMBSMBSchottky diode, 2 pins, Fagor ElectronicaSchottky diodeSMB2 pinsFagor Electronica
- What it is
- Schottky diode
- Maker
- Fagor Electronica
- Package
- SMB
- Pins
- 2
- Details
- Diode: SBR, 150V, 1A, Vf<0.95V(1A)
- Source
- Published code list
Is it dead? The meter test is below: Schottky diode.
FT533FaSOT-23-5LDO regulator, 5 pins, Fremont Micro DevicesLDO regulatorSOT-23-55 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-23-5
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FbSOT-23-5LDO regulator, 5 pins, Fremont Micro DevicesLDO regulatorSOT-23-55 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-23-5
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FcSOT-23-5LDO regulator, 5 pins, Fremont Micro DevicesLDO regulatorSOT-23-55 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-23-5
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FdSOT-353LDO regulator, 5 pins, Fremont Micro DevicesLDO regulatorSOT-3535 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-353
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FeSOT-353LDO regulator, 5 pins, Fremont Micro DevicesLDO regulatorSOT-3535 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-353
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FfSOT-353LDO regulator, 5 pins, Fremont Micro DevicesLDO regulatorSOT-3535 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-353
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FgSOT-23LDO regulator, 3 pins, Fremont Micro DevicesLDO regulatorSOT-233 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-23
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FhSOT-23LDO regulator, 3 pins, Fremont Micro DevicesLDO regulatorSOT-233 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-23
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FT533FiSOT-89LDO regulator, 3 pins, Fremont Micro DevicesLDO regulatorSOT-893 pinsFremont Micro Devices
- What it is
- LDO regulator
- Maker
- Fremont Micro Devices
- Package
- SOT-89
- Pins
- 3
- Details
- Linear voltage regulator IC: LDO, 2.7V±2%, 700mA
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
Gali-5FSOT-89RF amplifier (MMIC), 3 pins, Mini-CircuitsRF amplifier (MMIC)SOT-893 pinsMini-Circuits
- What it is
- RF amplifier (MMIC)
- Maker
- Mini-Circuits
- Package
- SOT-89
- Pins
- 3
- Details
- Lin-IC: RF amplifier, DC..4GHz, 15,1dB (50Ω)
- Source
- Published code list
Is it dead? The meter test is below: RF amplifier.
2 more parts have no package on record
CDZ7.5BZener diode, ROHMZener diodeNot recordedNot recordedROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Z-diode: 7,5V±2,5%, 40mA, 1W
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
CDZ55C5V6TZener diode, Crownpo TechnologyZener diodeNot recordedNot recordedCrownpo Technology
- What it is
- Zener diode
- Maker
- Crownpo Technology
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode: 5.32..5.88V, Zzt=30, Izt=5mA, 200mW
- Source
- Published code list
Is it dead? The meter test is below: Zener diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
RF amplifier
Voltage, board powered, on the output pin that the bias resistor or choke feeds.
Working, it reads
The output pin sits at the device voltage the datasheet gives, a few volts, below the supply.
Dead, it reads
- Output pin at 0 V, or near 0 Ω to ground with the power off: shorted inside.
- Output pin at the full supply voltage: open inside, no current flowing.
- On the board:
- Measured on the board with power on; the bias network is part of the reading.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The figures depend on the part and its bias resistor. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.