SMD code 5T in SOD-882
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
10 parts in SOD-882 are printed 5T
Not sure which one you have?
Answer up to 4 quick questions and these 36 parts are ranked, with a meter test that settles it. It works on a dead part too.
ES05DUCFBFKSOD-882ESD protection diode, 2 pins, ETEKESD protection diode2 pinsETEK
- What it is
- ESD protection diode
- Maker
- ETEK
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESD1006B5V0ASOD-882ESD protection diode, 2 pins, YFWESD protection diode2 pinsYFW
- What it is
- ESD protection diode
- Maker
- YFW
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDSLC5V0LBSOD-882ESD protection diode, 2 pins, Yangjie Electronic TechESD protection diode2 pinsYangjie Electronic Tech
- What it is
- ESD protection diode
- Maker
- Yangjie Electronic Tech
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
JEB05VCDFSOD-882TVS diode, 2 pins, JieJieTVS diode2 pinsJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
JEB05VCDF-AUSOD-882TVS diode, 2 pins, JieJieTVS diode2 pinsJieJie
- What it is
- TVS diode
- Maker
- JieJie
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
LESD8D15CT5GSOD-882ESD protection diode, 2 pins, LRCESD protection diode2 pinsLRC
- What it is
- ESD protection diode
- Maker
- LRC
- Package
- SOD-882
- Pins
- 2
- Details
- ESD protection diode, VRWM 15 V, IR @VRWM 0.3 μA, VBR Min 16 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
WE05DUCF-BSOD-882ESD protection diode, 2 pins, WayonESD protection diode2 pinsWayon
- What it is
- ESD protection diode
- Maker
- Wayon
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
WE5112KFSOD-882ESD protection diode, 2 pins, WayonESD protection diode2 pinsWayon
- What it is
- ESD protection diode
- Maker
- Wayon
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
WE5122KF-ATSOD-882ESD protection diode, 2 pins, WayonESD protection diode2 pinsWayon
- What it is
- ESD protection diode
- Maker
- Wayon
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
WE41135FSOD-882ESD protection diode, 2 pins, WayonESD protection diode2 pinsWayon
- What it is
- ESD protection diode
- Maker
- Wayon
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
5 more parts have no package on record. Nothing rules them out, so they stay.
LL05ABT1006-Q1ESD protection diode, Formosa MicrosemiESD protection diodeNot recordedFormosa Microsemi
- What it is
- ESD protection diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
PBZL82Zener diode, ROHMZener diodeNot recordedROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
PESD24VV1BSFESD protection diode, 2 pins, NexperiaESD protection diode2 pinsNexperia
- What it is
- ESD protection diode
- Maker
- Nexperia
- Package
- Not recorded
- Pins
- 2
- Details
- Very low capacitance high voltage bidirectional ESD protection diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SGM458BTGTemperature sensor, 4 pins, SG MicroTemperature sensor4 pinsSG Micro
- What it is
- Temperature sensor
- Maker
- SG Micro
- Package
- Not recorded
- Pins
- 4
- Details
- Low Power, Low Supply Voltage, CSP Package, Digital Temperature Sensor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
TCK22891GLoad switch, ToshibaLoad switchNot recordedToshiba
- What it is
- Load switch
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- TCK22xxxG, TCK2065G, TCK1024G
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 5T
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.