  • UMZ6.2KSOT-343Zener diode, 4 pins, ROHMZener diode4 pinsROHM
    What it is
    Zener diode
    Maker
    ROHM
    Package
    SOT-343
    Pins
    4
    Details
    Zener diode: Dual, 6.06..6.33V, Izt=5mA, 200mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • 14 more parts have no package on record. Nothing rules them out, so they stay.
    • ESDCAN27YPAFHESD protection diode, ROHMESD protection diodeNot recordedROHM
      What it is
      ESD protection diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient Voltage Suppressor (AEC-Q101 qualified)
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • MM3Z3V9BW-CZener diode, SeCoSZener diodeNot recordedSeCoS
      What it is
      Zener diode
      Maker
      SeCoS
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • SGM458HTGTemperature sensor, 4 pins, SG MicroTemperature sensor4 pinsSG Micro
      What it is
      Temperature sensor
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      4
      Details
      Low Power, Low Supply Voltage, CSP Package, Digital Temperature Sensor
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • SGM41107-62PF61YXDH4GBattery protection IC, 4 pins, SG MicroBattery protection IC4 pinsSG Micro
      What it is
      Battery protection IC
      Maker
      SG Micro
      Package
      Not recorded
      Pins
      4
      Details
      True Monolithic Li-Ion/Polymer Battery Protector in Tiny Thin Package
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5126C55A7R-GVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.5V±0.8%, -Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127C53ANRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.3V±0.8%, -Reset PPO, -MR, 50ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD5127N53FNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
      What it is
      Voltage supervisor
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.3V±0.8%, +Reset ODO, -MR, 50ms Rt delay
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • MM5Z47VZener diode, Fairchild SemiconductorZener diodeNot recordedFairchild Semiconductor
      What it is
      Zener diode
      Maker
      Fairchild Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • RP500N284ADC-DC converter, RicohDC-DC converterNot recordedRicoh
      What it is
      DC-DC converter
      Maker
      Ricoh
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM st-dwn, 2.8V±1.5%, 600mA, +CE, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • TCBZX584C47VZener diode, Tak Cheong SemiconductorZener diodeNot recordedTak Cheong Semiconductor
      What it is
      Zener diode
      Maker
      Tak Cheong Semiconductor
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Zener diode: 44..50V, Izt=2mA, Zzt=170, 200mW
      Source
      Published code list

      Is it dead? The meter test is below: Zener diode.

    • XC6126C55A7R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.5V±0.8%, -Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6127C53ANRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.3V±0.8%, -Reset PPO, -MR, Rdt=50ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6127N53FNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.3V±0.8%, +Reset ODO, -MR, Rdt=50ms
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • XC6129C53F9R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
      What it is
      Voltage supervisor
      Maker
      Torex
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 5.3V±0.8%, -Reset PPO, Rel. Delay, Det. Delay, Undef. Protect
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 5Z

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.