Skip to content

SMD code 60B

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

60B on a chip resistor

4.12 kΩ

4.12 kΩ resistor, 1%

EIA-96 precision code: 60 selects 4.12 from the E96 series and B multiplies by 1000. These are 1% parts.

Check it with a meter

Lift one end and measure across it. A good one reads 4.12 kΩ within 1%. Measuring it in circuit reads the parallel combination of everything around it, which is almost always lower, never higher: well above 4.12 kΩ on the board is a fault. Open, or well above 4.12 kΩ, means it has failed: burnt, cracked or corroded. That does not change what to fit: the marking still says 4.12 kΩ. A burnt resistor usually means the part it feeds drew too much, so find that before fitting a new one.

On a transistor or diode body (SOT-23-6, SMB, SOT-23-5), 60B is a part code instead. Those parts are listed below.

9 parts are printed 60B

Not sure which one you have?

Answer up to 4 quick questions and these 9 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • ET5H560BSOT-89LDO regulator, 3 pins, ETEKLDO regulatorSOT-893 pinsETEK
    What it is
    LDO regulator
    Maker
    ETEK
    Package
    SOT-89
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • ELM990221ACSOT-89LDO regulator, 3 pins, ELM TechnologyLDO regulatorSOT-893 pinsELM Technology
    What it is
    LDO regulator
    Maker
    ELM Technology
    Package
    SOT-89
    Pins
    3
    Details
    Linear voltage regulator IC: LDO, 2.2V±2%, 300mA
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • IXD5127N55BMRSOT-23-5Voltage supervisor, 5 pins, IXYSVoltage supervisorSOT-23-55 pinsIXYS
    What it is
    Voltage supervisor
    Maker
    IXYS
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 5.5V±0.8%, -Reset ODO, -MR, Rdt=100ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • MMBZ5260BPTSOT-23Zener diode, 3 pins, Chenmko EnterpriseZener diodeSOT-233 pinsChenmko Enterprise
    What it is
    Zener diode
    Maker
    Chenmko Enterprise
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode: 40.85..45.15V, Izt=3.0mA, Zzt=93, 225mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • MMHZ5260BPTSOD-123Zener diode, 2 pins, Chenmko EnterpriseZener diodeSOD-1232 pinsChenmko Enterprise
    What it is
    Zener diode
    Maker
    Chenmko Enterprise
    Package
    SOD-123
    Pins
    2
    Details
    Zener diode: 40.85..45.15V, Izt=3.0mA, Zzt=93, 225mW
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • PSMC5360BSMCZener diode, 2 pins, Plextron TechZener diodeSMC2 pinsPlextron Tech
    What it is
    Zener diode
    Maker
    Plextron Tech
    Package
    SMC
    Pins
    2
    Details
    Zener diode: 25V±5%, Zzt=4, Ipm=190mA, 5W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • RP102N131BSOT-23-5LDO regulator, 5 pins, RicohLDO regulatorSOT-23-55 pinsRicoh
    What it is
    LDO regulator
    Maker
    Ricoh
    Package
    SOT-23-5
    Pins
    5
    Details
    Linear voltage regulator IC: LDO, LN, 1.3V±1%, 300mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • SMC5360BSMCZener diode, 2 pins, Eris TechnologyZener diodeSMC2 pinsEris Technology
    What it is
    Zener diode
    Maker
    Eris Technology
    Package
    SMC
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • XC6127N55BMRSOT-23-5Voltage supervisor, 5 pins, TorexVoltage supervisorSOT-23-55 pinsTorex
    What it is
    Voltage supervisor
    Maker
    Torex
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 5.5V±0.8%, -Reset ODO, -MR, Rdt=100ms
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as 60B

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 1 more part.

Did you find your part?

Open this in the search to correct a character or try another package.