77 parts are printed 7-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
APL3527GWLCSPLoad switch, AnpecLoad switchWLCSPAnpec
- What it is
- Load switch
- Maker
- Anpec
- Package
- WLCSP
- Pins
- Not recorded
- Details
- Ultra-Low On-Resistance, Power Load Switch with Soft Start
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
APL3527HWLCSPLoad switch, AnpecLoad switchWLCSPAnpec
- What it is
- Load switch
- Maker
- Anpec
- Package
- WLCSP
- Pins
- Not recorded
- Details
- Ultra-Low On-Resistance, Power Load Switch with Soft Start
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
BAS170WSOD-323Switching diode, InfineonSwitching diodeSOD-323Infineon
- What it is
- Switching diode
- Maker
- Infineon
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BBY55-02VSOD-523InfineonNot recordedSOD-523Infineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
BBY55-03WSOD-323InfineonNot recordedSOD-323Infineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOD-323
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
CDZCV6.8BSOD-923ESD protection diode, ROHMESD protection diodeSOD-923ROHM
- What it is
- ESD protection diode
- Maker
- ROHM
- Package
- SOD-923
- Pins
- 2
- Details
- Transient Voltage Suppressor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESD5301N-2SOD-882TVS diode, WillsemiTVS diodeSOD-882Willsemi
- What it is
- TVS diode
- Maker
- Willsemi
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESD5341N-2SOD-882TVS diode, WillsemiTVS diodeSOD-882Willsemi
- What it is
- TVS diode
- Maker
- Willsemi
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ESDAXLC6-1MY2SOD-882TVS diode, STMicroelectronicsTVS diodeSOD-882STMicroelectronics
- What it is
- TVS diode
- Maker
- STMicroelectronics
- Package
- SOD-882
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ET74LVC1G07YDFNETEKNot recordedDFNETEK
- What it is
- Not recorded
- Maker
- ETEK
- Package
- DFN
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
ET74LVC1G17YDFNETEKNot recordedDFNETEK
- What it is
- Not recorded
- Maker
- ETEK
- Package
- DFN
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
ET74LVC1G17Y1DFNETEKNot recordedDFNETEK
- What it is
- Not recorded
- Maker
- ETEK
- Package
- DFN
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
3 more parts have no package on record
CDSP400-HFSwitching diode, ComchipSwitching diodeNot recordedComchip
- What it is
- Switching diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 90 V, 100 mA switching diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
CDZV3.6BZener diode, ROHMZener diodeNot recordedROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
ESD307-U1-02NESD protection diode, InfineonESD protection diodeNot recordedInfineon
- What it is
- ESD protection diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.