SMD code 86 in SOT-323
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
8 parts in SOT-323 are printed 86
Not sure which one you have?
Answer up to 4 quick questions and these 20 parts are ranked, with a meter test that settles it. It works on a dead part too.
DTC144WU3SOT-323Digital transistor (NPN, resistors built in), 3 pins, ROHMDigital transistor (NPN, resistors built in)3 pinsROHM
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- ROHM
- Package
- SOT-323
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
DTC144WUASOT-323Digital transistor (NPN, resistors built in), 3 pins, ROHMDigital transistor (NPN, resistors built in)3 pinsROHM
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- ROHM
- Package
- SOT-323
- Pins
- 3
- Details
- NPN 100mA 50V Digital Transistor (Bias Resistor Built-in Transistor)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
1PS70SB86SOT-3233 pins, NexperiaNot recorded3 pinsNexperia
- What it is
- Not recorded
- Maker
- Nexperia
- Package
- SOT-323
- Pins
- 3
- Details
- Si-diode: Dual, Schottky, UHF-Mix, 15V, 30mA, Vf<0,7V(30mA), 1pF
- Source
- Published code list
Is it dead? The meter test is below: Schottky diode.
2SC5186-FBSOT-323RF transistor, 3 pins, NEC ElectronicsRF transistor3 pinsNEC Electronics
- What it is
- RF transistor
- Maker
- NEC Electronics
- Package
- SOT-323
- Pins
- 3
- Details
- NPN transistor: uWave, LN, 5V, 30mA, 90mW, B=70..140, 13GHz
- Source
- Published code list
Is it dead? The meter test is below: Bipolar transistor.
AP8822N-56GTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisor3 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, Rdt=200ms, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-56PTSOT-323Voltage supervisor, 3 pins, Anwell SemiconductorVoltage supervisor3 pinsAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
BAT68-06WSOT-3233 pins, InfineonNot recorded3 pinsInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- SOT-323
- Pins
- 3
- Details
- gp dual ca Schottky 8V 130mA
- Source
- Published code list
Is it dead? The meter test is below: Schottky diode.
EC95810N56C1NSOT-323Voltage supervisor, 3 pins, E-CMOSVoltage supervisor3 pinsE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, Rdt=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
7 more parts have no package on record. Nothing rules them out, so they stay.
AD5113BCPZ80-RL78 pins, Analog DevicesNot recorded8 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- Not recorded
- Pins
- 8
- Source
- Published code list
Is it dead? The meter test is below: This part.
AP8822N-56GIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-56GSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, 200ms Rt delay, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-56PIVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8822N-56PSVoltage supervisor, Anwell SemiconductorVoltage supervisorNot recordedAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, 200ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95810N56C7IVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, Td=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95810N56C7SVoltage supervisor, E-CMOSVoltage supervisorNot recordedE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.6V±2%, -Reset ODO, Td=200ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 86
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Did you find your part?
Open this in the search to correct a character or try another package.