SMD code 8T in SOT-323
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in SOT-323 is printed 8T
Not sure which one you have?
Answer up to 4 quick questions and these 16 parts are ranked, with a meter test that settles it. It works on a dead part too.
APX803L40-27C3SOT-323Voltage supervisor, 3 pins, Diodes IncorporatedVoltage supervisor3 pinsDiodes Incorporated
- What it is
- Voltage supervisor
- Maker
- Diodes Incorporated
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 2.7V±1.5%, -Reset ODO, Rdt=450ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
14 more parts have no package on record. Nothing rules them out, so they stay.
FDME820NZTN-channel MOSFET, onsemiN-channel MOSFETNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- MOSFET - N-Channel, POWERTRENCH
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
PBZL110Zener diode, ROHMZener diodeNot recordedROHM
- What it is
- Zener diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
TCK22894GLoad switch, ToshibaLoad switchNot recordedToshiba
- What it is
- Load switch
- Maker
- Toshiba
- Package
- Not recorded
- Pins
- Not recorded
- Details
- TCK22xxxG, TCK2065G, TCK1024G
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Load switch.
AP7343D-20FS4-7BLDO regulator, Diodes IncorporatedLDO regulatorNot recordedDiodes Incorporated
- What it is
- LDO regulator
- Maker
- Diodes Incorporated
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 2.0V±1%, 300mA, +CE, CL
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
IXD5127C43DNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, -Reset PPO, -MR, 400ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
IXD5127N43JNRVoltage supervisor, IXYSVoltage supervisorNot recordedIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, +Reset ODO, -MR, 400ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127C43DNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, -Reset PPO, -MR, Rdt=400ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127N43JNRVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, +Reset ODO, -MR, Rdt=400ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6129C43J9R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, +Reset PPO, Detect Delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6129C43JNR-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, +Reset PPO, Detect Delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6129N43J9R-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, +Reset ODO, Detect Delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6129N43JNR-GVoltage supervisor, TorexVoltage supervisorNot recordedTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.3V±0.8%, +Reset ODO, Detect Delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6223A34B9R-GLDO regulator, TorexLDO regulatorNot recordedTorex
- What it is
- LDO regulator
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 3.45V±1%, 300mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
XC6223A34BNR-GLDO regulator, TorexLDO regulatorNot recordedTorex
- What it is
- LDO regulator
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Linear voltage regulator IC: LDO, 3.45V±1%, 300mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Load switch
Voltage, board powered, black probe on ground.
Working, it reads
Switched on, the output pin sits at the input voltage. Switched off, it sits near 0 V.
Dead, it reads
- Output at the input voltage while switched off: the pass element has shorted.
- Input present and switched on, no output: failed open, or shut down into a shorted load. Power off and measure output to ground.
- On the board:
- An output near 0 Ω to ground is usually the load. Lift the output pin to see which.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The pinout and whether the enable is active high or low differ between parts. The datasheet gives both.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as 8T
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 1 more part.
Did you find your part?
Open this in the search to correct a character or try another package.