SMD code A6 in SOT-723
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
1 part in SOT-723 is printed A6
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
BAS16M3SOT-723Switching diode, onsemiSwitching diodeonsemi
- What it is
- Switching diode
- Maker
- onsemi
- Package
- SOT-723
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
14 more parts have no package on record. Nothing rules them out, so they stay.
BAS16-02LSwitching diode, InfineonSwitching diodeInfineon
- What it is
- Switching diode
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
BZX884B3V9Zener diode, Good-ArkZener diodeGood-Ark
- What it is
- Zener diode
- Maker
- Good-Ark
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Zener diode, VZ 3.9 V, 0.25 W
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
FM4006-LRectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-L-Q1Rectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-MHRectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-MH-Q1Rectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-MSRectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-MS-Q1Rectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-MSTRectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-MST-Q1Rectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-SFRectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
FM4006-SF-Q1Rectifier, Formosa MicrosemiRectifierFormosa Microsemi
- What it is
- Rectifier
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Rectifier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
LBAS16TT1GSwitching diode, LRCSwitching diodeLRC
- What it is
- Switching diode
- Maker
- LRC
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Switching diode, VR 75 V, IF 200 mA, VF Max 1.25 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
LFCN-1325+RF filter, Mini-CircuitsRF filterMini-Circuits
- What it is
- RF filter
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LTCC filter
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as A6
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 1 more part.
Did you find your part?
Open this in the search to correct a character or try another package.