Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
41 parts are printed AAM
Not sure which one you have?
Answer up to 4 quick questions and these 41 parts are ranked, with a meter test that settles it. It works on a dead part too.
1.0SMBJ7.0CASMBTVS diode, 2 pins, SOCAYTVS diodeSMB2 pinsSOCAY
- What it is
- TVS diode
- Maker
- SOCAY
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
NCS20061SQ3SOT-323Operational amplifier, 3 pins, onsemiOperational amplifierSOT-3233 pinsonsemi
- What it is
- Operational amplifier
- Maker
- onsemi
- Package
- SOT-323
- Pins
- 3
- Details
- 3 MHz, 125 A Low Power Operational Amplifier
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
NCV20061SQ3SOT-323Operational amplifier, 3 pins, onsemiOperational amplifierSOT-3233 pinsonsemi
- What it is
- Operational amplifier
- Maker
- onsemi
- Package
- SOT-323
- Pins
- 3
- Details
- 3 MHz, 125 A Low Power Operational Amplifier
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SMAF7.0ASMAFTVS diode, 2 pins, Galaxy MicroelectronicsTVS diodeSMAF2 pinsGalaxy Microelectronics
- What it is
- TVS diode
- Maker
- Galaxy Microelectronics
- Package
- SMAF
- Pins
- 2
- Details
- 7V, 400W, Surface Mount TVS
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMAJ7.0ASMATVS diode, 2 pins, Galaxy MicroelectronicsTVS diodeSMA2 pinsGalaxy Microelectronics
- What it is
- TVS diode
- Maker
- Galaxy Microelectronics
- Package
- SMA
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
SMB10J7.0CASMBTVS diode, 2 pins, DOWOTVS diodeSMB2 pinsDOWO
- What it is
- TVS diode
- Maker
- DOWO
- Package
- SMB
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
TSMAJ7.0ASMATVS diode, 2 pins, Galaxy MicroelectronicsTVS diodeSMA2 pinsGalaxy Microelectronics
- What it is
- TVS diode
- Maker
- Galaxy Microelectronics
- Package
- SMA
- Pins
- 2
- Details
- 7V, 400W, Surface Mount TVS
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
TVJ10B7V0JB-HFSMBTVS diode, 2 pins, ComchipTVS diodeSMB2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMB
- Pins
- 2
- Details
- 7 V 1000 W bidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
FAN2508S28XSOT-23-5LDO regulator, 5 pins, Fairchild SemiconductorLDO regulatorSOT-23-55 pinsFairchild Semiconductor
- What it is
- LDO regulator
- Maker
- Fairchild Semiconductor
- Package
- SOT-23-5
- Pins
- 5
- Details
- Linear voltage regulator IC: LDO, 2.8V±2%, 50mA, +CE
- Source
- Published code list
Is it dead? The meter test is below: Voltage regulator.
FUF3MSMC2 pins, Fagor ElectronicaNot recordedSMC2 pinsFagor Electronica
- What it is
- Not recorded
- Maker
- Fagor Electronica
- Package
- SMC
- Pins
- 2
- Details
- Diode: U-fast recov. rectif, 1000V, 3A, Vf<1.7V(3A), 75ns
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
MAX823MXKSOT-3535 pins, Analog DevicesNot recordedSOT-3535 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-353
- Pins
- 5
- Source
- Published code list
Is it dead? The meter test is below: This part.
MAX1853XTSOT-3636 pins, Analog DevicesNot recordedSOT-3636 pinsAnalog Devices
- What it is
- Not recorded
- Maker
- Analog Devices
- Package
- SOT-363
- Pins
- 6
- Source
- Published code list
Is it dead? The meter test is below: This part.
3 more parts have no package on record
MMUN2217LDigital transistor (NPN, resistors built in), onsemiDigital transistor (NPN, resistors built in)Not recordedNot recordedonsemi
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Digital Transistors (BRT) R1 = 4.7 k , R2 = 10 k
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
NSVMMUN2217LDigital transistor (NPN, resistors built in), onsemiDigital transistor (NPN, resistors built in)Not recordedNot recordedonsemi
- What it is
- Digital transistor (NPN, resistors built in)
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Digital Transistors (BRT) R1 = 4.7 k , R2 = 10 k
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Digital transistor.
IXD9213B0M3DRDC-DC converter, ZilogDC-DC converterNot recordedNot recordedZilog
- What it is
- DC-DC converter
- Maker
- Zilog
- Package
- Not recorded
- Pins
- Not recorded
- Details
- DC/DC voltage converter IC: PWM st-dwn, 3.0MHz, 0.95V±2%, 1.5A, +CE
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Digital transistor
Ohms range, part lifted. The datasheet gives the built-in resistors: R1 in series with the base, R2 from base to emitter.
Working, it reads
Base to emitter reads about R1 plus R2 either way round, about 20 kΩ on a 10 k and 10 k part, give or take their wide tolerance. Collector to emitter reads open. A part with no R2 reads a junction behind R1 one way instead.
Dead, it reads
- Collector to emitter the same both ways, near 0 Ω with a continuous beep: shorted.
- From the base, open or far above R1 plus R2: R1 has failed. Static damage shows here most often.
- Base to emitter near 0 Ω: failed short.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- The readings depend on the resistor values, so an identical part elsewhere on the board is the surest reference. Measure it the same way.
- Watch for:
- On the diode range a good part with 10 kΩ resistors reads open on every pair, so a good part looks dead there. Use the ohms range.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Codes that begin with AAM
For a marking with its end worn or burnt off. Each code has a page of its own.
Codes not listed here are printed on 17 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.