SMD code AJp
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and AJ was searched.
137 parts are printed AJp
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
LD39020ADTPU33RDFNLDO regulator, STMicroelectronicsLDO regulatorDFNNot recordedSTMicroelectronics
- What it is
- LDO regulator
- Maker
- STMicroelectronics
- Package
- DFN
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
MM5Z3V9SOD-523Zener diode, 2 pins, onsemiZener diodeSOD-5232 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
MMBTH10M3SOT-723NPN transistor, 3 pins, onsemiNPN transistorSOT-7233 pinsonsemi
- What it is
- NPN transistor
- Maker
- onsemi
- Package
- SOT-723
- Pins
- 3
- Details
- NPN VHF/UHF Transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: NPN transistor.
MMBZ5232BSOT-23Zener diode, 3 pins, Formosa MicrosemiZener diodeSOT-233 pinsFormosa Microsemi
- What it is
- Zener diode
- Maker
- Formosa Microsemi
- Package
- SOT-23
- Pins
- 3
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
11 more parts have no package on record
J112N-channel MOSFET, onsemiN-channel MOSFETNot recordedNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-Channel Switch J111, J112, J113
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
J112-D26ZN-channel MOSFET, onsemiN-channel MOSFETNot recordedNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-Channel Switch J111, J112, J113
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
J112-D27ZN-channel MOSFET, onsemiN-channel MOSFETNot recordedNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-Channel Switch J111, J112, J113
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
J112-D74ZN-channel MOSFET, onsemiN-channel MOSFETNot recordedNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-Channel Switch J111, J112, J113
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
J113N-channel MOSFET, onsemiN-channel MOSFETNot recordedNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-Channel Switch J111, J112, J113
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
J113-D74ZN-channel MOSFET, onsemiN-channel MOSFETNot recordedNot recordedonsemi
- What it is
- N-channel MOSFET
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- N-Channel Switch J111, J112, J113
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: N-channel MOSFET.
NCP114AMX270LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage Regulator - CMOS Low Dropout
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
NCP139AFCT110LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LDO Regulator - Very Low Dropout, CMOS, Bias Rail
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
NCP139AFCTC110LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LDO Regulator - Very Low Dropout, CMOS, Bias Rail
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
NCP164ASN180LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LDO Regulator, 300 mA, Low Dropout Voltage, Ultra Low Noise, High PSRR with Power Good
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
NCP170AMX150LDO regulator, onsemiLDO regulatorNot recordedNot recordedonsemi
- What it is
- LDO regulator
- Maker
- onsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LDO Regulator - Ultra-Low I , CMOS
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Voltage regulator.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
N-channel MOSFET
Diode range, part lifted. Test drain to source first, then short gate to source and test again.
Working, it reads
Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.
Dead, it reads
- Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
- The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
- No body diode at all: failed open.
- On the board
- the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Voltage regulator
Voltage, board powered, black probe on ground. Then ohms with the power off.
Working, it reads
Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.
Dead, it reads
- Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
- Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
- Power off, input to output near 0 Ω: shorted.
- On the board:
- An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
- Compare:
- The same regulator on another rail or another board shows the right voltages and the right resistances.
- Watch for:
- Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
NPN transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.