Skip to content

SMD code AW in SOT-23-5

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 24 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • MAX825REUKSOT-23-55 pins, Analog DevicesNot recorded5 pinsAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    SOT-23-5
    Pins
    5
    Details
    CMOS-IC: Voltage Detector 2,63V, MR, ±Reset Push-pull output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • NL17SG00DFSOT-23-55 pins, onsemiNot recorded5 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-23-5
    Pins
    5
    Details
    CMOS logic IC: 2-input NAND gate
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • NL17SG00DFT2GSOT-23-55 pins, onsemiNot recorded5 pinsonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    SOT-23-5
    Pins
    5
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • PT7M7812MTASOT-23-5Voltage supervisor, 5 pins, Pericom TechnologyVoltage supervisor5 pinsPericom Technology
    What it is
    Voltage supervisor
    Maker
    Pericom Technology
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 4.38V±1.5%, +Reset PPO, -MR
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • PT7M7812MTAESOT-23-5Voltage supervisor, 5 pins, Pericom TechnologyVoltage supervisor5 pinsPericom Technology
    What it is
    Voltage supervisor
    Maker
    Pericom Technology
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 4.38V±1.5%, +Reset PPO, -MR, L-Free
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • S-80732SL-AWSOT-23-55 pins, ABLICNot recorded5 pinsABLIC
    What it is
    Not recorded
    Maker
    ABLIC
    Package
    SOT-23-5
    Pins
    5
    Details
    equivalent S-80732AL
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • SiP825REUSOT-23-5Voltage supervisor, 5 pins, VishayVoltage supervisor5 pinsVishay
    What it is
    Voltage supervisor
    Maker
    Vishay
    Package
    SOT-23-5
    Pins
    5
    Details
    CMOS-IC: Voltage Detector 2,63V, MR, ±Reset Push-pull output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • TLV71318PSOT-23-5LDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
    What it is
    LDO regulator
    Maker
    Texas Instruments
    Package
    SOT-23-5
    Pins
    5
    Details
    Capacitor-Free, 150-mA, Low-Dropout Regulator With Foldback Current Limit
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

  • 7 more parts have no package on record. Nothing rules them out, so they stay.
    • KDZ100VWZener diode, KECZener diodeNot recordedKEC
      What it is
      Zener diode
      Maker
      KEC
      Package
      Not recorded
      Pins
      Not recorded
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Zener diode.

    • NCP114AMX075LDO regulator, onsemiLDO regulatorNot recordedonsemi
      What it is
      LDO regulator
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage Regulator - CMOS Low Dropout
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: Voltage regulator.

    • TCM3-1TX+RF transformer, Mini-CircuitsRF transformerNot recordedMini-Circuits
      What it is
      RF transformer
      Maker
      Mini-Circuits
      Package
      Not recorded
      Pins
      Not recorded
      Details
      RF transformer, 2-500 MHz
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: This part.

    • VS5V0UA1VWMTVS diode, ROHMTVS diodeNot recordedROHM
      What it is
      TVS diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient Voltage Suppressor
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • VS5V0UA1VWMTFTVS diode, ROHMTVS diodeNot recordedROHM
      What it is
      TVS diode
      Maker
      ROHM
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Transient Voltage Suppressor
      Source
      Manufacturer datasheet

      Is it dead? The meter test is below: TVS or ESD protection diode.

    • 7WB3306AMXonsemiNot recordedNot recordedonsemi
      What it is
      Not recorded
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-Bit bus switch
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • 7WB3306BMXonsemiNot recordedNot recordedonsemi
      What it is
      Not recorded
      Maker
      onsemi
      Package
      Not recorded
      Pins
      Not recorded
      Details
      CMOS logic IC: 2-Bit bus switch
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as AW

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with AW

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 35 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.