SMD code BBp
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
The last letter, p, is lower case, which on NXP and Philips parts is a date or factory code, so it was set aside and BB was searched.
147 parts are printed BBp
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
AB01BAxialRectifier, 2 pins, SankenRectifierAxial2 pinsSanken
- What it is
- Rectifier
- Maker
- Sanken
- Package
- Axial
- Pins
- 2
- Details
- Fast Recovery Diode (VRM = 800 V, IF(AV) = 0.5 A, trr = 200 ns)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Silicon diode.
ATV04A190J-HFSMATVS diode, 2 pins, ComchipTVS diodeSMA2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMA
- Pins
- 2
- Details
- 19 V 400 W unidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
ATV06B190JB-HFSMBTVS diode, 2 pins, ComchipTVS diodeSMB2 pinsComchip
- What it is
- TVS diode
- Maker
- Comchip
- Package
- SMB
- Pins
- 2
- Details
- 19 V 600 W bidirectional TVS diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: TVS or ESD protection diode.
BAR81WSOT-343PIN diode, 4 pins, InfineonPIN diodeSOT-3434 pinsInfineon
- What it is
- PIN diode
- Maker
- Infineon
- Package
- SOT-343
- Pins
- 4
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
BAS40AGPSOT-23Schottky diode, 3 pins, ChenmkoSchottky diodeSOT-233 pinsChenmko
- What it is
- Schottky diode
- Maker
- Chenmko
- Package
- SOT-23
- Pins
- 3
- Details
- SCHOTTKY DIODE, 40 V, 0.2 A
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
BC846BPDWSOT-363Complementary transistor pair (NPN and PNP), 6 pins, Formosa MicrosemiComplementary transistor pair (NPN and PNP)SOT-3636 pinsFormosa Microsemi
- What it is
- Complementary transistor pair (NPN and PNP)
- Maker
- Formosa Microsemi
- Package
- SOT-363
- Pins
- 6
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor pair.
BC846PNSOT-363Transistor, 6 pins, YFWTransistorSOT-3636 pinsYFW
- What it is
- Transistor
- Maker
- YFW
- Package
- SOT-363
- Pins
- 6
- Details
- SMD General Purpose NPN+PNP Transistors
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
BCW61BSOT-23Transistor, 3 pins, InfineonTransistorSOT-233 pinsInfineon
- What it is
- Transistor
- Maker
- Infineon
- Package
- SOT-23
- Pins
- 3
- Details
- Bipolar transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
BRDBC8456SOT-363Transistor, 6 pins, Blue RocketTransistorSOT-3636 pinsBlue Rocket
- What it is
- Transistor
- Maker
- Blue Rocket
- Package
- SOT-363
- Pins
- 6
- Details
- Bipolar transistor
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Bipolar transistor.
BZT52H-C5V1SOD-123FZener diode, 2 pins, NexperiaZener diodeSOD-123F2 pinsNexperia
- What it is
- Zener diode
- Maker
- Nexperia
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
5 more parts have no package on record
ACDBQC0230R-HFSchottky diode, ComchipSchottky diodeNot recordedNot recordedComchip
- What it is
- Schottky diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 35 V, 0.2 A Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
BB555InfineonNot recordedNot recordedNot recordedInfineon
- What it is
- Not recorded
- Maker
- Infineon
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
BFCN-4800+RF filter, Mini-CircuitsRF filterNot recordedNot recordedMini-Circuits
- What it is
- RF filter
- Maker
- Mini-Circuits
- Package
- Not recorded
- Pins
- Not recorded
- Details
- LTCC filter, 4400-5200 MHz
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: This part.
BZX884B22LZener diode, VishayZener diodeNot recordedNot recordedVishay
- What it is
- Zener diode
- Maker
- Vishay
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 22 V Zener diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
CDBQC0230R-HFSchottky diode, ComchipSchottky diodeNot recordedNot recordedComchip
- What it is
- Schottky diode
- Maker
- Comchip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- 35 V, 0.2 A Schottky barrier diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
This part
Diode range and ohms range, part lifted.
Working, it reads
Depends on what it is. The datasheet, or an identical part, says.
Dead, it reads
- Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
- Open between every pair of pins: failed open, or a part that reads open when working.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor pair
Diode range, part lifted. Test each transistor on its own pins, as the datasheet's pinout gives them.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Bipolar transistor
Diode range, part lifted or its base leg off the pad.
Working, it reads
From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.
Dead, it reads
- Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
- The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
- Only one junction reads, or none: a junction has failed open. It then looks like a diode.
- A reading the wrong way round, where it should be open: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as BBp
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.
Codes not listed here are printed on 29 more parts.
Did you find your part?
Open this in the search to correct a character or try another package.