Skip to content

SMD code C in SOIC-8

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

13 parts have no package on record. Nothing rules them out, so they stay.

  • WAS3157D-6/TRAnalog switch, HXYAnalog switchNot recordedHXY
    What it is
    Analog switch
    Maker
    HXY
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Integrated circuit.

  • 3SK307N-channel MOSFET, PanasonicN-channel MOSFETNot recordedPanasonic
    What it is
    N-channel MOSFET
    Maker
    Panasonic
    Package
    Not recorded
    Pins
    Not recorded
    Details
    MOSFET n-type: Dual gate, VHF-amp, 15V, +30mA, 150mW, Idss=0..10mA
    Source
    Published code list

    Is it dead? The meter test is below: N-channel MOSFET.

  • BB5652 pins, InfineonNot recorded2 pinsInfineon
    What it is
    Not recorded
    Maker
    Infineon
    Package
    Not recorded
    Pins
    2
    Source
    An older or alternative marking, from a published code list

    Is it dead? The meter test is below: This part.

  • CDZ6.2BZener diode, ROHMZener diodeNot recordedROHM
    What it is
    Zener diode
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Z-diode: 6,2V±2,5%, 40mA, 1W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • CDZ15BZener diode, ROHMZener diodeNot recordedROHM
    What it is
    Zener diode
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Z-diode: 15V±2,5%, 20mA, 1W
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

  • CH3906T1PTPNP transistor, Chenmko EnterprisePNP transistorNot recordedChenmko Enterprise
    What it is
    PNP transistor
    Maker
    Chenmko Enterprise
    Package
    Not recorded
    Pins
    Not recorded
    Details
    PNP transistor: AF, Sw, 40V, 200mA, B=100..300, 250MHz
    Source
    Published code list

    Is it dead? The meter test is below: PNP transistor.

  • FSS16MSchottky diode, Fagor ElectronicaSchottky diodeNot recordedFagor Electronica
    What it is
    Schottky diode
    Maker
    Fagor Electronica
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Diode: SBR, 60V, 1A, Vf<0.64V(1A)
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • HMPP-38924 pins, BroadcomNot recorded4 pinsBroadcom
    What it is
    Not recorded
    Maker
    Broadcom
    Package
    Not recorded
    Pins
    4
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • HXTR-41054 pins, BroadcomNot recorded4 pinsBroadcom
    What it is
    Not recorded
    Maker
    Broadcom
    Package
    Not recorded
    Pins
    4
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • KV1832ETokNot recordedNot recordedTok
    What it is
    Not recorded
    Maker
    Tok
    Package
    Not recorded
    Pins
    Not recorded
    Details
    uhf varicap 4-17pf
    Source
    Published code list

    Is it dead? The meter test is below: PIN diode or varicap.

  • NE334S014 pins, RenesasNot recorded4 pinsRenesas
    What it is
    Not recorded
    Maker
    Renesas
    Package
    Not recorded
    Pins
    4
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • RN262CSROHMNot recordedNot recordedROHM
    What it is
    Not recorded
    Maker
    ROHM
    Package
    Not recorded
    Pins
    Not recorded
    Details
    HF pin diode
    Source
    Published code list

    Is it dead? The meter test is below: PIN diode or varicap.

  • TCR3UG09BLDO regulator, ToshibaLDO regulatorNot recordedToshiba
    What it is
    LDO regulator
    Maker
    Toshiba
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Linear voltage regulator IC: LDO, 0.9V±1%, 300mA, +CE
    Source
    Published code list

    Is it dead? The meter test is below: Voltage regulator.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

N-channel MOSFET

Diode range, part lifted. Test drain to source first, then short gate to source and test again.

Working, it reads

Red probe on the source, black on the drain: about 0.4 to 0.9 V, the body diode. Open the other way. The gate reads open to both other pins, both ways.

Dead, it reads

  • Drain to source the same both ways, near 0 V with a continuous beep, and still so after shorting gate to source: shorted. The classic failure.
  • The gate reads low to source or drain: gate shorted. Often all three pins end up shorted together.
  • No body diode at all: failed open.
On the board
the gate usually has a resistor to the source, so gate to source reads that resistor, which is not a fault. A drain short can be the load. Lift a leg to be sure.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
The diode range can charge the gate enough to turn the part on, and then drain to source reads near 0 both ways on a good part. Short gate to source and test again before you condemn it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PNP transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Black probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

PIN diode or varicap

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.6 to 0.9 V anode to cathode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.