SMD code C6-
Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.
170 parts are printed C6-
Not sure which one you have?
Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.
NZ8F33VSMX2WSOD-882Zener diode, 2 pins, onsemiZener diodeSOD-8822 pinsonsemi
- What it is
- Zener diode
- Maker
- onsemi
- Package
- SOD-882
- Pins
- 2
- Details
- Zener Diode Voltage Regulators NZ8F Series
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
PZ2FD27HASOD-882Zener diode, 2 pins, PrisemiZener diodeSOD-8822 pinsPrisemi
- What it is
- Zener diode
- Maker
- Prisemi
- Package
- SOD-882
- Pins
- 2
- Details
- Zener diode, 26.46 V, 18.9 V
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Zener diode.
RBR1LAM30ASOD-128Schottky diode, 2 pins, ROHMSchottky diodeSOD-1282 pinsROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- SOD-128
- Pins
- 2
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RBR1LAM30ATFSOD-128Schottky diode, 2 pins, ROHMSchottky diodeSOD-1282 pinsROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- SOD-128
- Pins
- 2
- Details
- Schottky Barrier Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RBR1MM30ASOD-123FSchottky diode, 2 pins, ROHMSchottky diodeSOD-123F2 pinsROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- SOD-123F
- Pins
- 2
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RBR1MM30ATFSOD-123FSchottky diode, 2 pins, ROHMSchottky diodeSOD-123F2 pinsROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- SOD-123F
- Pins
- 2
- Details
- Schottky Barrier Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SM160FL-CSOD-123FSchottky diode, 2 pins, SeCoSSchottky diodeSOD-123F2 pinsSeCoS
- What it is
- Schottky diode
- Maker
- SeCoS
- Package
- SOD-123F
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SMP1321-079LFSOD-523PIN diode, 2 pins, SkyworksPIN diodeSOD-5232 pinsSkyworks
- What it is
- PIN diode
- Maker
- Skyworks
- Package
- SOD-523
- Pins
- 2
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: PIN diode or varicap.
SN74LVC1G66DRYSONAnalog switch, 6 pins, Texas InstrumentsAnalog switchSON6 pinsTexas Instruments
- What it is
- Analog switch
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single Bilateral Analog Switch
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SN74LVC1G66DSFSONAnalog switch, 6 pins, Texas InstrumentsAnalog switchSON6 pinsTexas Instruments
- What it is
- Analog switch
- Maker
- Texas Instruments
- Package
- SON
- Pins
- 6
- Details
- Single Bilateral Analog Switch
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SN74LVC1G3157YDFNAnalog switch, UMWAnalog switchDFNNot recordedUMW
- What it is
- Analog switch
- Maker
- UMW
- Package
- DFN
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
4 more parts have no package on record
RBR1L30ASchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
RBR1L30ADDSchottky diode, ROHMSchottky diodeNot recordedNot recordedROHM
- What it is
- Schottky diode
- Maker
- ROHM
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Schottky Barrier Diode (AEC-Q101 qualified)
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Schottky diode.
SN74LVC1G66DRYRAnalog switch, UMWAnalog switchNot recordedNot recordedUMW
- What it is
- Analog switch
- Maker
- UMW
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
SN74LVC1G66DSFRAnalog switch, UMWAnalog switchNot recordedNot recordedUMW
- What it is
- Analog switch
- Maker
- UMW
- Package
- Not recorded
- Pins
- Not recorded
- Source
- Manufacturer datasheet
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Zener diode
Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.
Working, it reads
About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways, forward too: failed open.
- Holds well off its rated voltage on the supply test: drifted.
- A soft knee, or a voltage that creeps on the supply test: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Schottky diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- A reading the wrong way round as well: leaky.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
PIN diode or varicap
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.6 to 0.9 V anode to cathode, and open the other way.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A varicap that has drifted in capacitance reads normal on a meter. Only a capacitance meter or the tuning itself shows it.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Did you find your part?
Open this in the search to correct a character or try another package.