Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

32 parts are printed CB2

Not sure which one you have?

Answer up to 4 quick questions and these 32 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • GSEC24B180SOT-23ESD protection diode, 3 pins, Good-ArkESD protection diodeSOT-233 pinsGood-Ark
    What it is
    ESD protection diode
    Maker
    Good-Ark
    Package
    SOT-23
    Pins
    3
    Details
    ESD protection diode, VRWM 24 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • JEB24T2BSOT-23TVS diode, 3 pins, JieJieTVS diodeSOT-233 pinsJieJie
    What it is
    TVS diode
    Maker
    JieJie
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • JEB24T2B-AUSOT-23TVS diode, 3 pins, JieJieTVS diodeSOT-233 pinsJieJie
    What it is
    TVS diode
    Maker
    JieJie
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • MMSZ5231ESOD-123Zener diode, 2 pins, onsemiZener diodeSOD-1232 pinsonsemi
    What it is
    Zener diode
    Maker
    onsemi
    Package
    SOD-123
    Pins
    2
    Details
    Zener Voltage Regulators MMSZ52xxET1G Series, SZMMSZ52xxET1G Series
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • NL242BT23SOT-23ESD protection diode, 3 pins, Formosa MicrosemiESD protection diodeSOT-233 pinsFormosa Microsemi
    What it is
    ESD protection diode
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • NL242BT23-Q1SOT-23ESD protection diode, 3 pins, Formosa MicrosemiESD protection diodeSOT-233 pinsFormosa Microsemi
    What it is
    ESD protection diode
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SE24T2T02GZSOT-23TVS diode, 3 pins, SOCAYTVS diodeSOT-233 pinsSOCAY
    What it is
    TVS diode
    Maker
    SOCAY
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • AM61CC3302MSOT-23Voltage supervisor, 3 pins, Xiang Shuo ElectronicsVoltage supervisorSOT-233 pinsXiang Shuo Electronics
    What it is
    Voltage supervisor
    Maker
    Xiang Shuo Electronics
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 3.3V±2%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • AM61CC3302PSOT-89Voltage supervisor, 3 pins, Xiang Shuo ElectronicsVoltage supervisorSOT-893 pinsXiang Shuo Electronics
    What it is
    Voltage supervisor
    Maker
    Xiang Shuo Electronics
    Package
    SOT-89
    Pins
    3
    Details
    Voltage detector IC: 3.3V±2%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • HM61C3302MRSOT-23Voltage supervisor, 3 pins, Heermicr SemicconductorVoltage supervisorSOT-233 pinsHeermicr Semicconductor
    What it is
    Voltage supervisor
    Maker
    Heermicr Semicconductor
    Package
    SOT-23
    Pins
    3
    Details
    Voltage detector IC: 3.3V±2%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • HM61C3302NRSOT-23-5Voltage supervisor, 5 pins, Huamei SemiconductorVoltage supervisorSOT-23-55 pinsHuamei Semiconductor
    What it is
    Voltage supervisor
    Maker
    Huamei Semiconductor
    Package
    SOT-23-5
    Pins
    5
    Details
    Voltage detector IC: 3.3V±2%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • HM61C3302PRSOT-89Voltage supervisor, 3 pins, Heermicr SemicconductorVoltage supervisorSOT-893 pinsHeermicr Semicconductor
    What it is
    Voltage supervisor
    Maker
    Heermicr Semicconductor
    Package
    SOT-89
    Pins
    3
    Details
    Voltage detector IC: 3.3V±2%, +Reset PPO
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 3 more parts have no package on record
    • AM61CC3302NVoltage supervisor, Xiang Shuo ElectronicsVoltage supervisorNot recordedNot recordedXiang Shuo Electronics
      What it is
      Voltage supervisor
      Maker
      Xiang Shuo Electronics
      Package
      Not recorded
      Pins
      Not recorded
      Details
      Voltage detector IC: 3.3V±2%, +Reset PPO
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD3235B12C0R-GDC-DC converter, IXYSDC-DC converterNot recordedNot recordedIXYS
      What it is
      DC-DC converter
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM, st-dwn, 1.2V±2%, 600mA, 1.2MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD3235B12C4R-GDC-DC converter, IXYSDC-DC converterNot recordedNot recordedIXYS
      What it is
      DC-DC converter
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM, st-dwn, 1.2V±2%, 600mA, 1.2MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as CB2

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes not listed here are printed on 20 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.