Skip to content

SMD code D in SOD-323

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

15 parts have no package on record. Nothing rules them out, so they stay.

  • TCR3UG095ALDO regulator, ToshibaLDO regulatorNot recordedToshiba
    What it is
    LDO regulator
    Maker
    Toshiba
    Package
    Not recorded
    Pins
    Not recorded
    Details
    TCR3UG series
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • TCR4DG115LDO regulator, ToshibaLDO regulatorNot recordedToshiba
    What it is
    LDO regulator
    Maker
    Toshiba
    Package
    Not recorded
    Pins
    Not recorded
    Details
    TCR4DG series
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • TCR5RG105ALDO regulator, ToshibaLDO regulatorNot recordedToshiba
    What it is
    LDO regulator
    Maker
    Toshiba
    Package
    Not recorded
    Pins
    Not recorded
    Details
    TCR5RG series
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • TESDH5V0B05P1Q1ESD protection diode, Taiwan SemiconductorESD protection diodeNot recordedTaiwan Semiconductor
    What it is
    ESD protection diode
    Maker
    Taiwan Semiconductor
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TESDL24VB17P1Q1ESD protection diode, Taiwan SemiconductorESD protection diodeNot recordedTaiwan Semiconductor
    What it is
    ESD protection diode
    Maker
    Taiwan Semiconductor
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TPS7A0228PYCHLDO regulator, 4 pins, Texas InstrumentsLDO regulator4 pinsTexas Instruments
    What it is
    LDO regulator
    Maker
    Texas Instruments
    Package
    Not recorded
    Pins
    4
    Details
    Nanopower IQ, 25-nA, 200-mA, Low-Dropout Voltage Regulator With Fast Transient Response
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • TPS7A1011PYKALDO regulator, 5 pins, Texas InstrumentsLDO regulator5 pinsTexas Instruments
    What it is
    LDO regulator
    Maker
    Texas Instruments
    Package
    Not recorded
    Pins
    5
    Details
    300-mA, Low VIN, Low VOUT, Ultra-Low Dropout Regulator
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • TPS7A2018PYCKLDO regulator, 4 pins, Texas InstrumentsLDO regulator4 pinsTexas Instruments
    What it is
    LDO regulator
    Maker
    Texas Instruments
    Package
    Not recorded
    Pins
    4
    Details
    300mA, Ultra-Low-Noise, Low-IQ, High PSRR LDO
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Voltage regulator.

  • VBUS54DD-HS4ESD protection diode, VishayESD protection diodeNot recordedVishay
    What it is
    ESD protection diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    4-Line BUS-Port ESD Protection
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • VESD05A1B-HD1ESD protection diode, VishayESD protection diodeNot recordedVishay
    What it is
    ESD protection diode
    Maker
    Vishay
    Package
    Not recorded
    Pins
    Not recorded
    Details
    ESD Protection Diode in LLP1006-2L
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • WS7808QM-14WillsemiNot recordedNot recordedWillsemi
    What it is
    Not recorded
    Maker
    Willsemi
    Package
    Not recorded
    Pins
    Not recorded
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: This part.

  • 7WB3126CMXonsemiNot recordedNot recordedonsemi
    What it is
    Not recorded
    Maker
    onsemi
    Package
    Not recorded
    Pins
    Not recorded
    Details
    CMOS logic IC: 2-Bit bus switch
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • ESDAVLC6-1BF42 pins, STMicroelectronicsNot recorded2 pinsSTMicroelectronics
    What it is
    Not recorded
    Maker
    STMicroelectronics
    Package
    Not recorded
    Pins
    2
    Source
    Published code list

    Is it dead? The meter test is below: This part.

  • FS1DMRectifier, Fagor ElectronicaRectifierNot recordedFagor Electronica
    What it is
    Rectifier
    Maker
    Fagor Electronica
    Package
    Not recorded
    Pins
    Not recorded
    Details
    Diode: Rectifier, 200V, 1A, Vf<1.1V(1A), 1us
    Source
    Published code list

    Is it dead? The meter test is below: Silicon diode.

  • HMPP-38904 pins, BroadcomNot recorded4 pinsBroadcom
    What it is
    Not recorded
    Maker
    Broadcom
    Package
    Not recorded
    Pins
    4
    Source
    Published code list

    Is it dead? The meter test is below: This part.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

Voltage regulator

Voltage, board powered, black probe on ground. Then ohms with the power off.

Working, it reads

Input pin at the supply, output pin at its rated voltage, and the enable pin high if it has one.

Dead, it reads

  • Output equal to the input: the pass element has shorted. Everything after it may have taken the full input.
  • Input present, enable high, no output: failed open, or holding itself off into a shorted load. Power off and measure output to ground.
  • Power off, input to output near 0 Ω: shorted.
On the board:
An output at 0 V is often a shorted load with the regulator in current limit. Lift the output pin: if the short stays on the board, the regulator may be fine.
Compare:
The same regulator on another rail or another board shows the right voltages and the right resistances.
Watch for:
Makers put input, output and ground on different pins in the same package, so take them from this part's datasheet. Diode or ohms readings between its pins say little; check it powered.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Silicon diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways: failed open.
  • A reading the wrong way round as well: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Did you find your part?

Open this in the search to correct a character or try another package.

1 identification has been run against this marking.