Skip to content

SMD code DHE

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

25 parts are printed DHE

Not sure which one you have?

Answer up to 4 quick questions and these 25 parts are ranked, with a meter test that settles it. It works on a dead part too.

  • 3.0SMBJ110CASMBTVS diode, 2 pins, YFWTVS diodeSMB2 pinsYFW
    What it is
    TVS diode
    Maker
    YFW
    Package
    SMB
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 3.0SMCJ110CASMCFTVS diode, 2 pins, Formosa MicrosemiTVS diodeSMCF2 pinsFormosa Microsemi
    What it is
    TVS diode
    Maker
    Formosa Microsemi
    Package
    SMCF
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • 3.0SMCJ110CA-HFSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    110 V 3000 W bidirectional TVS diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ASMDJ110CA-HFSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    110 V 3000 W bidirectional TVS diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • ATV30C111JB-HFSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    110 V 3000 W bidirectional TVS diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • PAM32DOAB110CASMCTVS diode, 2 pins, ProTek DevicesTVS diodeSMC2 pinsProTek Devices
    What it is
    TVS diode
    Maker
    ProTek Devices
    Package
    SMC
    Pins
    2
    Details
    3000 Watt TVS Component
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMDJ110CASMCTVS diode, 2 pins, SOCAYTVS diodeSMC2 pinsSOCAY
    What it is
    TVS diode
    Maker
    SOCAY
    Package
    SMC
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMDJ110CA-MSSMCTVS diode, 2 pins, MSKSEMITVS diodeSMC2 pinsMSKSEMI
    What it is
    TVS diode
    Maker
    MSKSEMI
    Package
    SMC
    Pins
    2
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • SMDJ110CA-SSMCTVS diode, 2 pins, ProTek DevicesTVS diodeSMC2 pinsProTek Devices
    What it is
    TVS diode
    Maker
    ProTek Devices
    Package
    SMC
    Pins
    2
    Details
    3000 Watt TVS Component
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • TV30C111JB-HFSMCTVS diode, 2 pins, ComchipTVS diodeSMC2 pinsComchip
    What it is
    TVS diode
    Maker
    Comchip
    Package
    SMC
    Pins
    2
    Details
    110 V 3000 W bidirectional TVS diode
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: TVS or ESD protection diode.

  • IXD3236B1EDER-GUSP-6CDC-DC converter, 6 pins, IXYSDC-DC converterUSP-6C6 pinsIXYS
    What it is
    DC-DC converter
    Maker
    IXYS
    Package
    USP-6C
    Pins
    6
    Details
    DC/DC voltage converter IC: PWM/PFM, st-dwn, 1.45V±2%, 600mA, 3MHz, Vin>2V, HSST, CL
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • IXD3236B1EDMR-GSOT-23-5DC-DC converter, 5 pins, IXYSDC-DC converterSOT-23-55 pinsIXYS
    What it is
    DC-DC converter
    Maker
    IXYS
    Package
    SOT-23-5
    Pins
    5
    Details
    DC/DC voltage converter IC: PWM/PFM, st-dwn, 1.45V±2%, 600mA, 3MHz, Vin>2V, HSST, CL
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • 3 more parts have no package on record
    • AD5121BCPZ10-RL716 pins, Analog DevicesNot recordedNot recorded16 pinsAnalog Devices
      What it is
      Not recorded
      Maker
      Analog Devices
      Package
      Not recorded
      Pins
      16
      Source
      Published code list

      Is it dead? The meter test is below: This part.

    • IXD3236B1ED0R-GDC-DC converter, IXYSDC-DC converterNot recordedNot recordedIXYS
      What it is
      DC-DC converter
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM/PFM, st-dwn, 1.45V±2%, 600mA, 3MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

    • IXD3236B1ED4R-GDC-DC converter, IXYSDC-DC converterNot recordedNot recordedIXYS
      What it is
      DC-DC converter
      Maker
      IXYS
      Package
      Not recorded
      Pins
      Not recorded
      Details
      DC/DC voltage converter IC: PWM/PFM, st-dwn, 1.45V±2%, 600mA, 3MHz, Vin>2V, HSST, CL
      Source
      Published code list

      Is it dead? The meter test is below: Integrated circuit.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

TVS or ESD protection diode

Diode range, from the protected line to ground, part lifted if you can.

Working, it reads

A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.

Dead, it reads

  • From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
  • A reading both ways on a one-way part: leaky.
  • A one-way part open both ways: failed open.
On the board
, a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
Compare:
The same part on the next line or connector pin is the healthy reading to compare with.
Watch for:
A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

This part

Diode range and ohms range, part lifted.

Working, it reads

Depends on what it is. The datasheet, or an identical part, says.

Dead, it reads

  • Between two pins, the same reading both ways, near 0 V with a continuous beep: shorted.
  • Open between every pair of pins: failed open, or a part that reads open when working.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Printed with a code easy to misread as DHE

One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.

Codes that begin with DHE

For a marking with its end worn or burnt off. Each code has a page of its own.

Did you find your part?

Open this in the search to correct a character or try another package.