AP8821C-40GTSOT-323Voltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821C-40PTSOT-323Voltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95808C40C1NSOT-323Voltage supervisor, E-CMOSVoltage supervisorE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- SOT-323
- Pins
- 3
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
HSMP-381BSOT-323Agilent TechnologiesNot recordedAgilent Technologies
- What it is
- Not recorded
- Maker
- Agilent Technologies
- Package
- SOT-323
- Pins
- 3
- Details
- HP3810 pin atten diode
- Source
- Published code list
Is it dead? The meter test is below: Silicon diode.
11 more parts have no package on record. Nothing rules them out, so they stay.
AP1702ATWAnachipNot recordedAnachip
- What it is
- Not recorded
- Maker
- Anachip
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector, 4,63V, Reset Push-pull output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821C-40GIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821C-40GSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO, H-free
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821C-40PIVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
AP8821C-40PSVoltage supervisor, Anwell SemiconductorVoltage supervisorAnwell Semiconductor
- What it is
- Voltage supervisor
- Maker
- Anwell Semiconductor
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95808C40C7IVoltage supervisor, E-CMOSVoltage supervisorE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
EC95808C40C7SVoltage supervisor, E-CMOSVoltage supervisorE-CMOS
- What it is
- Voltage supervisor
- Maker
- E-CMOS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 4.0V±2%, -Reset PPO
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
ESD7Z3.3TVS diode, Formosa MicrosemiTVS diodeFormosa Microsemi
- What it is
- TVS diode
- Maker
- Formosa Microsemi
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Transient voltage supressor: Vrwm=3.3V, Vbr=5.0V, 11.9A, 113W(20ms)
- Source
- Published code list
Is it dead? The meter test is below: TVS or ESD protection diode.
IXD5127C55KNRVoltage supervisor, IXYSVoltage supervisorIXYS
- What it is
- Voltage supervisor
- Maker
- IXYS
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.5V±0.8%, +Reset PPO, -MR, 800ms Rt delay
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6GC4002HRTorexNot recordedTorex
- What it is
- Not recorded
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- CMOS-IC: Voltage Detector 4,0V, Reset Push-pull output
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
XC6127C55KNRVoltage supervisor, TorexVoltage supervisorTorex
- What it is
- Voltage supervisor
- Maker
- Torex
- Package
- Not recorded
- Pins
- Not recorded
- Details
- Voltage detector IC: 5.5V±0.8%, +Reset PPO, -MR, Rdt=800ms
- Source
- Published code list
Is it dead? The meter test is below: Integrated circuit.
Is it dead? One meter test per kind
Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.
Integrated circuit
Voltage with the board powered; ohms from each pin to ground with it off.
Working, it reads
Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.
Dead, it reads
- A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
- Supply present, output stuck: failed, or its load has.
- On the board:
- A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
- Compare:
- The surest reference is the same IC on a working board, measured pin by pin.
- Watch for:
- Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Silicon diode
Diode range, part lifted or one leg off the pad. Red probe on the anode.
Working, it reads
About 0.5 to 0.8 V anode to cathode, and open the other way. Small switching diodes read about 0.6 to 0.7 V; large rectifiers can read a little lower.
Dead, it reads
- The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
- Open both ways: failed open.
- A reading the wrong way round as well: leaky.
- On the board
- this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
- Compare:
- If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
- Watch for:
- A three-pin body can hold two diodes. With a common pin they read two junctions from that pin, just like a transistor; in series they read two drops end to end. Test each pair the datasheet names.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
TVS or ESD protection diode
Diode range, from the protected line to ground, part lifted if you can.
Working, it reads
A one-way part reads about 0.6 to 0.8 V forward and open in reverse. A two-way part reads open both ways. Arrays with several lines read as the datasheet's diagram draws them.
Dead, it reads
- From the line to ground, the same reading both ways, near 0 V with a continuous beep: shorted.
- A reading both ways on a one-way part: leaky.
- A one-way part open both ways: failed open.
- On the board
- , a line reading shorted to ground can be this part or anything else on that line. Lift it: if the short goes with it, it has failed.
- Compare:
- The same part on the next line or connector pin is the healthy reading to compare with.
- Watch for:
- A two-way part reads open both ways when it is good, exactly like one that has failed open. The meter cannot tell them apart; an identical part on the next line can.
A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.
Printed with a code easy to misread as E0
One character differs, and it is one that is easy to confuse under a lamp. Each code has a page of its own.