Skip to content

SMD code EH in SOT-23

Marking codes are not standardised, and the same code is reused by unrelated makers for unrelated parts. Below is every part in our tables printed with it, and any printed with a code that is easy to misread as it, from the manufacturers' own marking tables and published code lists.

Not sure which one you have?

Answer up to 4 quick questions and these 50 parts are ranked, with a meter test that settles it. It works on a dead part too.

all SOT-23, 3 pins. What differs:

  • ABCW66H-HFSOT-23NPN transistor, ComchipNPN transistorComchip
    What it is
    NPN transistor
    Maker
    Comchip
    Package
    SOT-23
    Pins
    3
    Details
    45 V, 0.8 A NPN transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • BCW66HSOT-23NPN transistor, InfineonNPN transistorInfineon
    What it is
    NPN transistor
    Maker
    Infineon
    Package
    SOT-23
    Pins
    3
    Details
    75V, 0.8A, General Purpose NPN Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • BZX84B30SOT-23Zener diode, DiotecZener diodeDiotec
    What it is
    Zener diode
    Maker
    Diotec
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84B30ASOT-23Zener diode, Formosa MicrosemiZener diodeFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • BZX84B30A-Q1SOT-23Zener diode, Formosa MicrosemiZener diodeFormosa Microsemi
    What it is
    Zener diode
    Maker
    Formosa Microsemi
    Package
    SOT-23
    Pins
    3
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • GSBCW66-HSOT-23NPN transistor, Good-ArkNPN transistorGood-Ark
    What it is
    NPN transistor
    Maker
    Good-Ark
    Package
    SOT-23
    Pins
    3
    Details
    NPN transistor, 45 V, 0.8 A
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • LBAS70-05LT1GSOT-23Schottky diode, LRCSchottky diodeLRC
    What it is
    Schottky diode
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Schottky diode, VR 70 V, IF 0.07 A, VF Max 0.41 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • MMBZ4716SOT-23Zener diode, Good-ArkZener diodeGood-Ark
    What it is
    Zener diode
    Maker
    Good-Ark
    Package
    SOT-23
    Pins
    3
    Details
    Zener diode, VZ 39 V, 0.35 W
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Zener diode.

  • S-LBAS70-05LT1GSOT-23Schottky diode, LRCSchottky diodeLRC
    What it is
    Schottky diode
    Maker
    LRC
    Package
    SOT-23
    Pins
    3
    Details
    Schottky diode, VR 70 V, IF 0.07 A, VF Max 0.41 V
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: Schottky diode.

  • TBCW66HSOT-23NPN transistor, Galaxy MicroelectronicsNPN transistorGalaxy Microelectronics
    What it is
    NPN transistor
    Maker
    Galaxy Microelectronics
    Package
    SOT-23
    Pins
    3
    Details
    45V, 0.8A, General Purpose NPN Bipolar Transistor
    Source
    Manufacturer datasheet

    Is it dead? The meter test is below: NPN transistor.

  • 1SS365SOT-23Sanyo ElectricNot recordedSanyo Electric
    What it is
    Not recorded
    Maker
    Sanyo Electric
    Package
    SOT-23
    Pins
    3
    Details
    schottky UHF det/mix
    Source
    Published code list

    Is it dead? The meter test is below: Schottky diode.

  • AP1703BWSOT-23Voltage supervisor, Diodes IncorporatedVoltage supervisorDiodes Incorporated
    What it is
    Voltage supervisor
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    CMOS-IC: Voltage Detector, 4,38V, -Reset Push-pull output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • BCW66HTASOT-23Diodes IncorporatedNot recordedDiodes Incorporated
    What it is
    Not recorded
    Maker
    Diodes Incorporated
    Package
    SOT-23
    Pins
    3
    Details
    NPN medium power transistor
    Source
    Published code list

    Is it dead? The meter test is below: Bipolar transistor.

  • MAX6326UR22SOT-23Analog DevicesNot recordedAnalog Devices
    What it is
    Not recorded
    Maker
    Analog Devices
    Package
    SOT-23
    Pins
    3
    Details
    CMOS-IC: Voltage Detector 2,2V, -Reset Push-pull output
    Source
    Published code list

    Is it dead? The meter test is below: Integrated circuit.

  • MMVZ4716SOT-23VishayNot recordedVishay
    What it is
    Not recorded
    Maker
    Vishay
    Package
    SOT-23
    Pins
    3
    Details
    zener 350mW 5% 39V
    Source
    Published code list

    Is it dead? The meter test is below: Zener diode.

Is it dead? One meter test per kind

Parts of the same kind are tested the same way, so each test is here once. Each part above points to its own.

NPN transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

Red probe on the base reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Zener diode

Diode range for the forward check, part lifted, red probe on the anode. A bench supply for the Zener voltage.

Working, it reads

About 0.6 to 0.8 V forward and open in reverse on the diode range. Its Zener voltage shows only on a supply: feed it through a resistor that sets about 5 mA, cathode to positive, read quickly, and it should hold near its rated voltage.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • Open both ways, forward too: failed open.
  • Holds well off its rated voltage on the supply test: drifted.
  • A soft knee, or a voltage that creeps on the supply test: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A meter's diode range stops at about 2 to 3 V, so almost every Zener reads open in reverse on it, good or bad; a 3 V meter may just show a 2.4 or 2.7 V part. Above about 3 V the meter cannot tell a Zener from a plain diode.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Schottky diode

Diode range, part lifted or one leg off the pad. Red probe on the anode.

Working, it reads

About 0.15 to 0.45 V anode to cathode, roughly half a silicon diode, and open the other way.

Dead, it reads

  • The same reading both ways round, near 0 V with a continuous beep or the same middling value: shorted.
  • A reading the wrong way round as well: leaky.
  • Open both ways: failed open.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A large Schottky can read about 0.1 V forward and beep like a short, and leaks a little the wrong way when good, more when warm. It is shorted only if it reads the same both ways. Measure it cold, beside an identical cold one.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Integrated circuit

Voltage with the board powered; ohms from each pin to ground with it off.

Working, it reads

Supply pin at its voltage and the output doing what the datasheet says. Readings between pins depend on the part.

Dead, it reads

  • A pin near 0 Ω to ground or to the supply pin where an identical part does not read that: failed short.
  • Supply present, output stuck: failed, or its load has.
On the board:
A pin shorted to ground on the board can be anything on that net. Lift the pin to be sure.
Compare:
The surest reference is the same IC on a working board, measured pin by pin.
Watch for:
Its protection diodes can read like junctions between pins, even like a transistor. That proves nothing either way.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Bipolar transistor

Diode range, part lifted or its base leg off the pad.

Working, it reads

From the base, one probe colour reads about 0.6 to 0.75 V to the emitter and to the collector, and open the other way round. Collector to emitter reads open both ways.

Dead, it reads

  • Collector to emitter the same both ways, near 0 V with a continuous beep: shorted. The commonest failure.
  • The base the same both ways to another pin, near 0 V or a middling value: a shorted junction.
  • Only one junction reads, or none: a junction has failed open. It then looks like a diode.
  • A reading the wrong way round, where it should be open: leaky.
On the board
this is a first look only: the meter reads every path between those pins, and a short can be a neighbour. Lift one leg before you condemn it.
Compare:
If an identical part sits elsewhere on the board, measure it the same way: that is what this one should read.
Watch for:
A pair of diodes with a common pin reads just like a transistor, and some transistors carry a built-in diode or resistor. The datasheet says which.

A dead part still carries its marking. A short or an open says it has failed, not that it is a different part.

Codes that begin with EH

For a marking with its end worn or burnt off. Each code has a page of its own.

Codes not listed here are printed on 26 more parts.

Did you find your part?

Open this in the search to correct a character or try another package.